Suppr超能文献

低收缩复合材料是否适用于正畸托槽粘结?

Are the low-shrinking composites suitable for orthodontic bracket bonding?

作者信息

Buyuk Suleyman Kutalmis, Cantekin Kenan, Demirbuga Sezer, Ali Ozturk Mehmet

机构信息

Department of Orthodontics, Faculty of Dentistry, Erciyes University, Kayseri, Turkey.

Department of Pediatric Dentistry, Faculty of Dentistry,Erciyes University, Kayseri, Turkey.

出版信息

Eur J Dent. 2013 Jul;7(3):284-288. doi: 10.4103/1305-7456.115411.

Abstract

PURPOSE

To evaluate the shear bond strength (SBS), adhesive remnant index (ARI), and microleakage of low-shrinking and conventional composites used as an orthodontic bracket bonding adhesive.

MATERIALS AND METHODS

A hundred twenty non-caries human premolars, extracted for orthodontic purposes, were used in this study. Sixty of them were separated into two groups. Brackets were bonded to the teeth in the test group with Silorane (3M-Espe) and control group with Transbond-XT (3M-Unitek). SBS values of these brackets were recorded in MPa using a universal testing machine. ARI scores were determined after the failure of brackets. The remaining 60 teeth were divided into two groups and microleakage was evaluated by the dye penetration method. Statistical analyses were performed by Wilcoxon, Pearson Chi-square, and Mann-Whitney U tests at P < 0.05 level.

RESULTS

The mean SBS for Transbond XT was significantly greater than low-shrinking composite (P < 0.001). Significant differences (χ(2) =29.60, P < 0.001) were present between the two groups for the ARI scores. Microleakage values were lower in low-shrinking composite than in the control group, and this difference was found to be statistically significant (P < 0.001).

CONCLUSIONS

Although low-shrinking composite produced insufficient SBS and ARI scores, microleakage values were lower in low-shrinking composite than in the control group on the etched enamel surfaces, when used as a bracket bonding composite.

摘要

目的

评估用作正畸托槽粘结剂的低收缩复合树脂和传统复合树脂的剪切粘结强度(SBS)、粘结剂残留指数(ARI)及微渗漏情况。

材料与方法

本研究使用了120颗因正畸需要拔除的无龋人类前磨牙。其中60颗被分为两组。试验组使用Silorane(3M - Espe)将托槽粘结到牙齿上,对照组使用Transbond - XT(3M - Unitek)。使用万能试验机以兆帕(MPa)记录这些托槽的SBS值。托槽脱落后确定ARI评分。其余60颗牙齿分为两组,采用染料渗透法评估微渗漏情况。采用Wilcoxon检验、Pearson卡方检验和Mann - Whitney U检验进行统计学分析,检验水准为P < 0.05。

结果

Transbond XT的平均SBS显著高于低收缩复合树脂(P < 0.001)。两组的ARI评分存在显著差异(χ(2)=29.60,P < 0.001)。低收缩复合树脂的微渗漏值低于对照组,且差异具有统计学意义(P < 0.001)。

结论

尽管低收缩复合树脂产生的SBS和ARI评分不足,但当用作托槽粘结复合树脂时,在酸蚀釉质表面,低收缩复合树脂的微渗漏值低于对照组。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/17af/4053616/e38b4e2ce42c/EJD-7-284-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验