粘结剂类型和厚度对聚纤维桩粘结的影响。

Influence of cement type and thickness on polyfiber post adhesion.

作者信息

Uzunoğlu Emel, Türker Sevinç Aktemur, Yilmaz Zeliha

机构信息

Department of Endodontics, Faculty of Dentistry, Hacettepe University, Sihhiye 06100, Ankara, Turkey.

Department of Endodontics, Bulent Ecevit University, Zonguldak, Turkey.

出版信息

J Conserv Dent. 2014 May;17(3):255-60. doi: 10.4103/0972-0707.131789.

Abstract

INTRODUCTION

To evaluate the effect of two different post space diameters and related resin cement film thicknesses on the bond strength of a polyfiber post.

MATERIALS AND METHODS

A total of 48 premolars were randomly divided into two according to the post space diameter: 1.1 mm and 1.5 mm. Then each group was divided into three sub-groups according to luting cement used: RelyX U100, Panavia F2.0/ED primer, Clearfil SA cement. Spirapost was then luted into the canal using luting cements. Two slices were obtained from each root specimen. Push-out tests were performed. Data was analyzed with Kruskal-Wallis and Connover post-hoc and Mann-Whitney U-test (P < 0.05).

RESULTS

Push-out bond strength was found to vary significantly according to type of adhesive system and post space diameter size (P < 0.05). The self-adhesive resin cement RelyX U100 had significantly higher bond strengths compared with the other adhesive system (P < 0.05). The self-etch adhesive system (Panavia F2.0) showed significantly lower bond strengths compared with the other systems (P < 0.05). There was a significant interaction between the luting systems and post space diameter (P < 0.05).

CONCLUSION

The increases in post space diameter significantly reduced the bond strength of Spirapost to root dentine for both groups.

摘要

引言

评估两种不同桩道直径及相关树脂水门汀薄膜厚度对聚纤维桩粘结强度的影响。

材料与方法

根据桩道直径将48颗前磨牙随机分为两组:1.1毫米和1.5毫米。然后根据使用的粘结水门汀将每组再分为三个亚组:RelyX U100、Panavia F2.0/ED底漆、Clearfil SA水门汀。接着使用粘结水门汀将Spirapost桩粘固于根管内。从每个牙根标本获取两片切片。进行推出试验。数据采用Kruskal-Wallis检验、Connover事后检验和Mann-Whitney U检验进行分析(P < 0.05)。

结果

发现推出粘结强度根据粘结系统类型和桩道直径大小有显著差异(P < 0.05)。自粘结树脂水门汀RelyX U100与其他粘结系统相比具有显著更高的粘结强度(P < 0.05)。自酸蚀粘结系统(Panavia F2.0)与其他系统相比显示出显著更低的粘结强度(P < 0.05)。粘结系统和桩道直径之间存在显著交互作用(P < 0.05)。

结论

对于两组而言,桩道直径的增加显著降低了Spirapost桩与牙根牙本质的粘结强度。