Luthria Archana, Srirekha A, Hegde Jayshree, Karale Rupali, Tyagi Sanjana, Bhaskaran Sajeev
Department of Conservative Dentistry and Endodontics, The Oxford Dental College, Hospital and Research Centre, Bommanhalli, Hosur Road, Bangalore, Karnataka, India.
J Conserv Dent. 2012 Oct;15(4):372-6. doi: 10.4103/0972-0707.101914.
The aim of this study was to evaluate the fracture resistance of endodontically treated maxillary premolars with wide mesio-occluso-distal (MOD) cavities restored with either composite resin, or composite resin reinforced with different types of fibres.
Fifty human maxillary premolars were selected. Five intact teeth served as positive controls. Endodontic therapy was carried out in the remaining forty-five teeth. Standardized MOD cavities were prepared in all the teeth. The teeth were restored with a nanocomposite using an incremental technique. These forty five teeth were randomly divided into three experimental groups (Group A, B and C) (n = 15). The teeth in Group A did not undergo any further procedures. The teeth in Group B and C were reinforced with composite impregnated glass fibre and polyethylene fibre, respectively. Fracture resistance was measured in Newtons (N).
The positive controls showed the highest mean fracture resistance (811.90 N), followed by Group B (600.49N), Group A (516.96N) and Group C (514.64N), respectively. One Way analysis of variance (ANOVA) test revealed a statistically significant difference between all the groups (P = 0.001). Post-hoc Tukey test revealed a moderately significant difference (P = 0.034) between Control and Group B, and a strongly significant difference between Control and Group A (P = 0.002), and Control and Group C (P = 0.001).
Endodontic therapy and MOD cavity preparation significantly reduced the fracture resistance of endodontically treated maxillary premolars (P = 0.001). No statistically significant difference was found between the experimental groups (Group A, B and C) (P > 0.1). However, the fracture resistance of the composite impregnated glass fibre reinforced group was much higher than the others.
本研究旨在评估用复合树脂或不同类型纤维增强的复合树脂修复近中-咬合-远中(MOD)宽洞的经根管治疗的上颌前磨牙的抗折性。
选取50颗人上颌前磨牙。5颗完整牙齿作为阳性对照。对其余45颗牙齿进行根管治疗。所有牙齿制备标准化的MOD洞。采用分层技术用纳米复合树脂修复牙齿。这45颗牙齿随机分为三个实验组(A组、B组和C组)(每组n = 15)。A组牙齿未进行任何进一步处理。B组和C组牙齿分别用复合浸渍玻璃纤维和聚乙烯纤维增强。以牛顿(N)为单位测量抗折性。
阳性对照显示平均抗折性最高(811.90 N),其次分别是B组(600.49 N)、A组(516.96 N)和C组(514.64 N)。单因素方差分析(ANOVA)检验显示所有组之间存在统计学显著差异(P = 0.001)。事后Tukey检验显示对照组与B组之间存在中度显著差异(P = 0.034),对照组与A组(P = 0.002)以及对照组与C组(P = 0.001)之间存在高度显著差异。
根管治疗和MOD洞制备显著降低了经根管治疗的上颌前磨牙的抗折性(P = 0.001)。实验组(A组、B组和C组)之间未发现统计学显著差异(P > 0.1)。然而,复合浸渍玻璃纤维增强组的抗折性远高于其他组。