ENVOLURE SAS, 1682 rue de la Valsière, 34184, Montpellier cedex 4, France.
Environ Sci Pollut Res Int. 2014 Dec;21(23):13642-5. doi: 10.1007/s11356-014-3202-3. Epub 2014 Jun 21.
BOD5 dates back to 1912 when the Royal Commission decided to use the mean residence time of water in the rivers of England, 5 days, as a standard to measure the biochemical oxygen demand. Initially designed to protect the quality of river waters from extensive sewage discharge, the use of BOD5 has been quickly extended to waste water treatment plants (WWTPs) to monitor their efficiency on a daily basis. The measurement has been automatized but remains a tedious, time- and resource-consuming analysis. We have cross-validated a surrogate BOD5 method on two sites in France and in the USA with a total of 109 samples. This method uses a fluorescent redox indicator on a 96-well microplate to measure microbial catabolic activity for a large number of samples simultaneously. Three statistical tests were used to compare surrogate and reference methods and showed robust equivalence.
BOD5 可追溯到 1912 年,当时皇家委员会决定将英国河流中 5 天的平均停留时间作为衡量生化需氧量的标准。最初设计用于保护河流水质免受大量污水排放的影响,BOD5 的使用已迅速扩展到污水处理厂 (WWTP) 以监测其日常效率。该测量已实现自动化,但仍然是一项繁琐、耗时且资源密集型的分析。我们在法国和美国的两个地点共对 109 个样本进行了替代 BOD5 方法的交叉验证。该方法使用 96 孔微孔板上的荧光氧化还原指示剂同时测量大量样本的微生物代谢活性。三种统计检验用于比较替代方法和参考方法,结果显示具有稳健的等效性。