1 Department of Radiology, Seattle Children's Hospital, Seattle, WA.
AJR Am J Roentgenol. 2014 Jul;203(1):W85-91. doi: 10.2214/AJR.13.10794.
Determining the optimal CT technique to minimize patient radiation exposure while maintaining diagnostic utility requires patient-specific protocols that are based on patient characteristics. This work develops relationships between different anthropometrics and CT image noise to determine appropriate protocol classification schemes.
We measured the image noise in 387 CT examinations of pediatric patients (222 boys, 165 girls) of the chest, abdomen, and pelvis and generated mathematic relationships between image noise and patient lateral and anteroposterior dimensions, age, and weight.
At the chest level, lateral distance (ld) across the body is strongly correlated with weight (ld = 0.23 × weight + 16.77; R(2) = 0.93) and is less well correlated with age (ld = 1.10 × age + 17.13; R(2) = 0.84). Similar trends were found for anteroposterior dimensions and at the abdomen level. Across all studies, when acquisition-specific parameters are factored out of the noise, the log of image noise was highly correlated with lateral distance (R(2) = 0.72) and weight (R(2) = 0.72) and was less correlated with age (R(2) = 0.62). Following first-order relationships of image noise and scanner technique, plots were formed to show techniques that could achieve matched noise across the pediatric population.
Patient lateral distance and weight are essentially equally effective metrics to base maximum technique settings for pediatric patient-specific protocols. These metrics can also be used to help categorize appropriate reference levels for CT technique and size-specific dose estimates across the pediatric population.
确定能够在维持诊断效能的同时使患者接受的辐射剂量最小化的最优 CT 技术,需要根据患者特征制定针对特定患者的方案。本项工作旨在确定不同人体测量学指标与 CT 图像噪声之间的关系,以确定适当的方案分类方案。
我们测量了 387 例儿科患者(男 222 例,女 165 例)胸部、腹部和骨盆 CT 检查的图像噪声,并生成了图像噪声与患者的左右径、前后径、年龄和体重之间的数学关系。
在胸部水平,身体的左右径(ld)与体重呈强相关性(ld = 0.23 ×体重+16.77;R² = 0.93),与年龄的相关性稍差(ld = 1.10 ×年龄+17.13;R² = 0.84)。在前后径和腹部水平也发现了类似的趋势。在所有研究中,当将特定于采集的参数从噪声中剔除时,图像噪声的对数与左右径(R² = 0.72)和体重(R² = 0.72)高度相关,与年龄的相关性稍差(R² = 0.62)。根据图像噪声与扫描仪技术的一阶关系,绘制了图以显示可以在儿科人群中实现匹配噪声的技术。
患者的左右径和体重基本等效,都可以作为儿科特定患者方案最大技术设置的指标。这些指标还可以用于帮助确定儿科人群中 CT 技术和大小特异性剂量估计的适当参考水平。