Cook-Cunningham Sheri Lynn
Department of Music Education, University of Central Arkansas, Arkansas, USA.
Noise Health. 2014 May-Jun;16(70):143-8. doi: 10.4103/1463-1741.134914.
This study investigated the accuracy, reliability, and characteristics of three brands of personal noise dosimeters (N = 7 units) in both pink noise (PN) environments and natural environments (NEs) through the acquisition of decibel readings, Leq readings and noise doses. Acquisition periods included repeated PN conditions, choir room rehearsals and participant (N = 3) Leq and noise dosages procured during a day in the life of a music student. Among primary results: (a) All dosimeters exhibited very strong positive correlations for PN measurements across all instruments; (b) all dosimeters were within the recommended American National Standard Institute (ANSI) SI.25-1991 standard of ±2 dB (A) of a reference measurement; and (c) all dosimeters were within the recommended ANSI SI.25-1991 standard of ±2 dB (A) when compared with each other. Results were discussed in terms of using personal noise dosimeters within hearing conservation and research contexts and recommendations for future research. Personal noise dosimeters were studied within the contexts of PN environments and NEs (choral classroom and the day in the life of collegiate music students). This quantitative study was a non-experimental correlation design. Three brands of personal noise dosimeters (Cirrus doseBadge, Quest Edge Eg5 and Etymotic ER200D) were tested in two environments, a PN setting and a natural setting. There were two conditions within each environment. In the PN environment condition one, each dosimeter was tested individually in comparison with two reference measuring devices (Ivie and Easera) while PN was generated by a Whites Instrument PN Tube. In condition two, the PN procedures were replicated for longer periods while all dosimeters measured the sound levels simultaneously. In the NE condition one, all dosimeters were placed side by side on a music stand and recorded sound levels of choir rehearsals over a 7-h rehearsal period. In NE, condition two noise levels were measured during a day in the life of college music students. Three participants each wore two types of dosimeters for an 8-h period during a normal school day. Descriptive statistical analyzes including means, standard deviation and Pearson product-moment correlation. The primary finding is that the dosimeters in this study recorded results within ±2 dB of either a reference measurement or within dosimeters in all four conditions examined. All dosimeters studied measured steady noise source accurately and consistently, with strong positive correlations across all instruments. Measurements acquired during choral rehearsals indicated a maximum of 1.5 dB difference across dosimeters. The Etymotic research personal noise dosimeters (ER200D) could provide individuals and schools of music with a relatively inexpensive tool to monitor sound doses. Findings from this study suggest that the three brands of dosimeters tested will provide reliable Leq levels and hearing dosages in both PN and natural settings.
本研究通过获取分贝读数、等效连续A声级(Leq)读数和噪声剂量,调查了三个品牌的个人噪声剂量计(共7台)在粉红噪声(PN)环境和自然环境(NE)中的准确性、可靠性及特性。采集周期包括重复的PN条件、合唱教室排练,以及在一名音乐专业学生一天的生活中获取的参与者(n = 3)的Leq和噪声剂量。主要结果如下:(a)所有剂量计在所有仪器的PN测量中均呈现出非常强的正相关;(b)所有剂量计均在推荐的美国国家标准学会(ANSI)SI.25 - 1991标准规定的参考测量值±2 dB(A)范围内;(c)相互比较时,所有剂量计均在推荐的ANSI SI.25 - 1991标准规定的±2 dB(A)范围内。研究结果从在听力保护和研究背景下使用个人噪声剂量计的角度进行了讨论,并对未来研究提出了建议。在PN环境和NE(合唱教室以及大学音乐专业学生一天的生活)背景下对个人噪声剂量计进行了研究。这项定量研究是一种非实验性相关设计。三个品牌的个人噪声剂量计(Cirrus doseBadge、Quest Edge Eg5和Etymotic ER200D)在两种环境中进行了测试,即PN环境和自然环境。每个环境中有两个条件。在PN环境条件一中,每个剂量计与两个参考测量设备(Ivie和Easera)单独进行测试,同时由Whites Instrument PN Tube产生PN。在条件二中,PN程序在更长时间内重复进行,同时所有剂量计同时测量声级。在NE条件一中,所有剂量计并排放置在乐谱架上,记录7小时排练期间合唱排练的声级。在NE条件二中,在大学音乐专业学生一天的生活中测量噪声水平。三名参与者在正常上课日的8小时内每人佩戴两种类型的剂量计。进行了描述性统计分析,包括均值、标准差和皮尔逊积矩相关性分析。主要发现是,本研究中的剂量计在所有四个测试条件下,记录的结果与参考测量值相差±2 dB以内,或在剂量计之间相差±2 dB以内。所有研究的剂量计都能准确且一致地测量稳定噪声源,所有仪器之间呈现出很强的正相关。合唱排练期间获取的数据表明,各剂量计之间的最大差异为1.5 dB。Etymotic研究型个人噪声剂量计(ER200D)可为个人和音乐学校提供一种相对廉价的工具来监测声音剂量。本研究结果表明,所测试的三个品牌的剂量计在PN和自然环境中都能提供可靠的Leq水平和听力剂量。