Suppr超能文献

氟-18-氟脱氧葡萄糖正电子发射断层扫描在胆管癌患者原发性肿瘤评估中的诊断准确性:一项荟萃分析。

Diagnostic accuracy of fluorine-18-fluorodeoxyglucose positron emission tomography in the evaluation of the primary tumor in patients with cholangiocarcinoma: a meta-analysis.

作者信息

Annunziata Salvatore, Caldarella Carmelo, Pizzuto Daniele Antonio, Galiandro Federica, Sadeghi Ramin, Giovanella Luca, Treglia Giorgio

机构信息

Institute of Nuclear Medicine, Catholic University of the Sacred Heart, Largo Agostino Gemelli 8, 00168 Rome, Italy.

Postgraduate School of General Surgery, Catholic University of the Sacred Heart, Largo Agostino Gemelli 8, 00168 Rome, Italy.

出版信息

Biomed Res Int. 2014;2014:247693. doi: 10.1155/2014/247693. Epub 2014 May 13.

Abstract

OBJECTIVE

To meta-analyze published data about the diagnostic accuracy of fluorine-18-fluorodeoxyglucose ((18)F-FDG) positron emission tomography (PET) or PET/computed tomography (PET/CT) for primary tumor evaluation in patients with cholangiocarcinoma (CCa).

METHODS

A comprehensive literature search of studies published through December 31, 2013, was performed. Pooled sensitivity and specificity were calculated on a per patient based analysis. Subgroup analyses considering the device used (PET versus PET/CT) and the localization of the primary tumor (intrahepatic cholangiocarcinoma (IH-CCa), extrahepatic cholangiocarcinoma (EH-CCa), and hilar cholangiocarcinoma (H-CCa)) were carried out.

RESULTS

Twenty-three studies including 1232 patients were included in the meta-analysis. Pooled sensitivity and specificity of (18)F-FDG-PET or PET/CT were 81% and 82%, respectively. Pooled sensitivity and specificity, respectively, were 80% and 89% for PET, 82% and 75% for PET/CT, 95% and 83% for IH-CCa, 84% and 95% for H-CCa, and 76% and 74% for EH-CCa.

CONCLUSIONS

(18)F-FDG-PET and PET/CT were demonstrated to be accurate diagnostic imaging methods for primary tumor evaluation in patients with CCa. These tools have a better diagnostic accuracy in patients with IH-CCa than in patients with EH-CCa. Further studies are needed to evaluate the accuracy of (18)F-FDG-PET or PET/CT in patients with H-CCa.

摘要

目的

对已发表的关于氟-18-氟脱氧葡萄糖((18)F-FDG)正电子发射断层扫描(PET)或PET/计算机断层扫描(PET/CT)用于胆管癌(CCa)患者原发性肿瘤评估的诊断准确性的数据进行荟萃分析。

方法

对截至2013年12月31日发表的研究进行全面的文献检索。基于每位患者的分析计算合并敏感性和特异性。进行了亚组分析,考虑了所使用的设备(PET与PET/CT)以及原发性肿瘤的定位(肝内胆管癌(IH-CCa)、肝外胆管癌(EH-CCa)和肝门部胆管癌(H-CCa))。

结果

荟萃分析纳入了23项研究,共1232例患者。(18)F-FDG-PET或PET/CT的合并敏感性和特异性分别为81%和82%。PET的合并敏感性和特异性分别为80%和89%,PET/CT为82%和75%,IH-CCa为95%和83%,H-CCa为84%和95%,EH-CCa为76%和74%。

结论

(18)F-FDG-PET和PET/CT被证明是用于CCa患者原发性肿瘤评估的准确诊断成像方法。这些工具在IH-CCa患者中的诊断准确性优于EH-CCa患者。需要进一步研究来评估(18)F-FDG-PET或PET/CT在H-CCa患者中的准确性。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/a40c/4052790/1e7a47342fee/BMRI2014-247693.001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验