Ryu Seong Yeol, Greenwood-Quaintance Kerryl E, Hanssen Arlen D, Mandrekar Jayawant N, Patel Robin
Division of Clinical Microbiology, Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, MN 55905, USA.
Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN 55905, USA.
Diagn Microbiol Infect Dis. 2014 Aug;79(4):448-53. doi: 10.1016/j.diagmicrobio.2014.03.021. Epub 2014 Apr 12.
We previously described a rapid PCR panel targeting bacteria associated with prosthetic joint infection (PJI) for use on biofilms dislodged from explanted hip and knee arthroplasties. Herein, we tested the PCR panel on periprosthetic tissues from 95 subjects undergoing resection knee arthroplasty, all of whom had had tissue cultures performed. A subset also had synovial fluid culture (n=89) and/or device vortexing and sonication with culture (n=58), and a subset of these PCR (n=36) of resulting sonicate fluid, performed. Of the 64 subjects with PJI, 10 and 44 had positive tissue PCR and cultures, respectively, one of whom had a positive tissue PCR with negative tissue cultures. The overall sensitivity of tissue PCR (16%) was much lower than that of tissue (69%), synovial fluid (72%) and sonicate fluid (77%) culture as well as sonicate fluid PCR (78%) (P < 0.00001, P < 0.00001, P < 0.00001, and P=0.0003, respectively). Periprosthetic tissue PCR, as performed herein, has poor sensitivity for PJI diagnosis.
我们之前描述了一种针对与人工关节感染(PJI)相关细菌的快速PCR检测板,用于对从取出的髋关节和膝关节置换术中脱落的生物膜进行检测。在此,我们对95例接受膝关节置换术切除的患者的假体周围组织进行了PCR检测板测试,所有患者均进行了组织培养。一部分患者还进行了滑液培养(n = 89)和/或对装置进行涡旋和超声处理后培养(n = 58),并对其中一部分患者的超声处理后的液体进行了PCR检测(n = 36)。在64例PJI患者中,分别有10例和44例组织PCR和培养结果为阳性,其中1例组织PCR阳性但组织培养阴性。组织PCR的总体敏感性(16%)远低于组织培养(69%)、滑液培养(72%)、超声处理后液体培养(77%)以及超声处理后液体PCR(78%)(P分别<0.00001、<0.00001、<0.00001和=0.0003)。本文所进行的假体周围组织PCR对PJI诊断的敏感性较差。