Suppr超能文献

Dependence of fibrinolytic activity on the concentration of free rather than total tissue-type plasminogen activator in plasma after pharmacologic administration.

作者信息

Lucore C L, Fujii S, Sobel B E

机构信息

Cardiovascular Division, Washington University, School of Medicine, St. Louis, Missouri 63110.

出版信息

Circulation. 1989 Jun;79(6):1204-13. doi: 10.1161/01.cir.79.6.1204.

Abstract

To identify factors responsible for the decline of plasma tissue-type plasminogen activator (t-PA)-specific activity that we have observed after infusions of the activator and to define the potential usefulness of selected variants of t-PA in obviating them in patients with infarction, serial plasma samples from patients (n = 4) and rabbits (n = 15) given t-PA were assayed for total t-PA antigen, t-PA activity, and free as opposed to type-1 plasminogen activator inhibitor (PAI-1)--complexed t-PA. In patients, attenuation of t-PA specific activity after infusions was evident with concentrations of total t-PA antigen that were as much as sevenfold greater than pretreatment values (62 compared with 9 ng/ml). Attenuation of t-PA activity corresponded with the disappearance of free t-PA from plasma and was associated with persistence of complexes of t-PA with PAI-1. In normal rabbits (n = 4) given wild-type t-PA by bolus injection, PAI-1 activity was 4 +/- 1 arbitrary units/ml. Attenuation of t-PA activity was not evident until 60 minutes after injection at a time when total plasma t-PA antigen concentration was as low as 13 +/- 8 ng/ml. Under these conditions, plasma t-PA was composed predominantly of free t-PA. In rabbits (n = 5) given lipopolysaccharide to increase plasma PAI-1 activity to 193 +/- 84 arbitrary units/ml, the specific activity of t-PA was attenuated as early as 15 minutes after injection at a time when total t-PA antigen concentration was as high as 164 +/- 79 ng/ml. As was the case with samples from patients, attenuation was associated with the disappearance of free t-PA and the persistence of complexes of t-PA with PAI-1. A genetically engineered variant of t-PA with comparable specific activity and a comparable rate constant of association with PAI-1 but designed to persist in the circulation manifested prolonged clearance from plasma of normal rabbits (n = 3) (t1/2 = 24.6 +/- 1.6 minutes compared with an alpha phase t1/2 of 1.9 minutes for wild-type t-PA). The variant lacked the epidermal growth factor and kringle one domains and contained a duplicated kringle two domain.(ABSTRACT TRUNCATED AT 400 WORDS)

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验