Suppr超能文献

使用短半衰期原位制备放射性源对放射性核素校准仪进行比对的创新方法。

Innovative methodology for intercomparison of radionuclide calibrators using short half-life in situ prepared radioactive sources.

作者信息

Oliveira P A, Santos J A M

机构信息

Centro de Investigação do Instituto Português de Oncologia do Porto Francisco Gentil, EPE, Porto, Portugal and Departamento de Física e Astronomia, Faculdade de Ciências da Universidade do Porto, Portugal.

Centro de Investigação do Instituto Português de Oncologia do Porto Francisco Gentil, EPE, Porto, Portugal; Serviço de Física Médica do Instituto Português de Oncologia do Porto Francisco Gentil, EPE, Porto, Portugal; Serviço de Medicina Nuclear do Instituto Português de Oncologia do Porto Francisco Gentil, EPE, Porto, Portugal; and Instituto de Ciências Biomédicas Abel Salazar, Universidade do Porto, Porto, Portugal.

出版信息

Med Phys. 2014 Jul;41(7):072507. doi: 10.1118/1.4884035.

Abstract

PURPOSE

An original radionuclide calibrator method for activity determination is presented. The method could be used for intercomparison surveys for short half-life radioactive sources used in Nuclear Medicine, such as(99m)Tc or most positron emission tomography radiopharmaceuticals.

METHODS

By evaluation of the resulting net optical density (netOD) using a standardized scanning method of irradiated Gafchromic XRQA2 film, a comparison of the netOD measurement with a previously determined calibration curve can be made and the difference between the tested radionuclide calibrator and a radionuclide calibrator used as reference device can be calculated. To estimate the total expected measurement uncertainties, a careful analysis of the methodology, for the case of(99m)Tc, was performed: reproducibility determination, scanning conditions, and possible fadeout effects. Since every factor of the activity measurement procedure can influence the final result, the method also evaluates correct syringe positioning inside the radionuclide calibrator.

RESULTS

As an alternative to using a calibrated source sent to the surveyed site, which requires a relatively long half-life of the nuclide, or sending a portable calibrated radionuclide calibrator, the proposed method uses a source preparedin situ. An indirect activity determination is achieved by the irradiation of a radiochromic film using (99m)Tc under strictly controlled conditions, and cumulated activity calculation from the initial activity and total irradiation time. The irradiated Gafchromic film and the irradiator, without the source, can then be sent to a National Metrology Institute for evaluation of the results.

CONCLUSIONS

The methodology described in this paper showed to have a good potential for accurate (3%) radionuclide calibrators intercomparison studies for(99m)Tc between Nuclear Medicine centers without source transfer and can easily be adapted to other short half-life radionuclides.

摘要

目的

介绍一种用于活度测定的新型放射性核素校准仪方法。该方法可用于核医学中使用的短半衰期放射源的比对测量,如(99m)Tc或大多数正电子发射断层显像放射性药物。

方法

通过使用标准化扫描方法对辐照后的Gafchromic XRQA2胶片的净光密度(netOD)进行评估,可以将netOD测量值与先前确定的校准曲线进行比较,并计算被测放射性核素校准仪与用作参考设备的放射性核素校准仪之间的差异。为了估计总的预期测量不确定度,针对(99m)Tc的情况,对方法进行了仔细分析:重复性测定、扫描条件以及可能的褪色效应。由于活度测量过程的每个因素都会影响最终结果,该方法还评估放射性核素校准仪内注射器的正确定位。

结果

作为向被调查地点发送需要相对长半衰期核素校准源或发送便携式校准放射性核素校准仪的替代方法,所提出的方法使用现场制备的源。通过在严格控制的条件下使用(99m)Tc辐照放射变色胶片,并根据初始活度和总辐照时间计算累积活度,实现间接活度测定。然后可以将辐照后的Gafchromic胶片和无源辐照器发送到国家计量机构进行结果评估。

结论

本文所述方法在无需源转移的情况下,对核医学中心之间的(99m)Tc放射性核素校准仪进行准确(3%)比对研究方面具有良好潜力,并且可以轻松适用于其他短半衰期放射性核素。