Abstract

Considering the enzymatic activity of the cytochrome P450 2D6 on substrates such as codeine, the current paper includes the development of an enzymatic biosensor for detection of this drug. Home-made screen-printed electrodes were used as electrochemical transducers of the biosensor, in which the enzyme was covalently attached to the carbon surface of the working electrode, this type of modification being the most suitable for the immobilization of the biological element. Chronoamperometric measurements were carried out under optimum conditions of pH and working potential, pH 7 and +200 mV vs. screen-printed Ag/AgCl electrode, giving a reduction signal related to the concentration of codeine in solution. Consecutive additions of a solution of codeine were performed to obtain calibration curves in order to validate the electrochemical method in terms of precision and calculate its capability of detection. These biosensors were used for the determination of codeine in urine and commercial pharmaceutical samples.

摘要

考虑到细胞色素P450 2D6对可待因等底物的酶活性,本文介绍了一种用于检测该药物的酶生物传感器的研制。自制的丝网印刷电极用作生物传感器的电化学换能器,其中酶通过共价键附着在工作电极的碳表面,这种修饰类型最适合生物元件的固定化。计时电流法测量在pH值和工作电位的最佳条件下进行,pH值为7,相对于丝网印刷Ag/AgCl电极的工作电位为+200 mV,产生与溶液中可待因浓度相关的还原信号。连续添加可待因溶液以获得校准曲线,以便在精密度方面验证电化学方法并计算其检测能力。这些生物传感器用于测定尿液和市售药品样品中的可待因。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验