Jackson Mary L, Kerl Marie E, Tynan Beth, Mann F A
Department of Veterinary Medicine and Surgery, University of Missouri College of Veterinary Medicine, 900 East Campus Drive, Columbia, MO, 65211.
J Vet Emerg Crit Care (San Antonio). 2014 Jul-Aug;24(4):408-13. doi: 10.1111/vec.12205.
To establish reference intervals for whole blood and plasma colloid osmotic pressure (COP) in healthy cats between the ages of 1 and 10 years using a cage-side colloid osmometer.
Prospective, observational study.
University veterinary teaching hospital.
Sixty-three healthy cats.
Phlebotomy.
Whole blood COP mean was 24.4 (±2.78) mmHg and plasma COP mean was 24.3 (±2.59) mmHg. Reference interval for our study population of feline whole blood COP was 18.9 to 30.4 mmHg, and for our study population of feline plasma COP was 18.3 to 30.8 mmHg. Difference of paired whole blood COP and plasma COP was +0.23 ± 1.68 mmHg (P = 0.32). There was no significant difference when comparing COP from neutered male and neutered female cats. Total protein and albumin were significantly correlated with whole blood COP (total protein to whole blood COP P < 0.0001, r = 0.53; albumin to whole blood COP P <0.0001, r = 0.68) and plasma COP (total protein to plasma COP P = 0.0025, r = 0.41; albumin to plasma COP P < 0.0001, r = 0.66).
No significant difference was found between mean whole blood and plasma COP in this study population of cats. Even though not statistically significant, evaluation of paired whole blood COP and plasma COP did reveal a slight difference; therefore, it seems prudent to maintain sample consistency for serial evaluations in cats.
使用床边胶体渗透压计建立1至10岁健康猫全血和血浆胶体渗透压(COP)的参考区间。
前瞻性观察性研究。
大学兽医教学医院。
63只健康猫。
静脉穿刺采血。
全血COP均值为24.4(±2.78)mmHg,血浆COP均值为24.3(±2.59)mmHg。本研究猫全血COP的参考区间为18.9至30.4 mmHg,猫血浆COP的参考区间为18.3至30.8 mmHg。配对的全血COP与血浆COP差值为+0.23±1.68 mmHg(P = 0.32)。比较去势公猫和去势母猫的COP时无显著差异。总蛋白和白蛋白与全血COP显著相关(总蛋白与全血COP,P < 0.0001,r = 0.53;白蛋白与全血COP,P < 0.0001,r = 0.68)以及与血浆COP显著相关(总蛋白与血浆COP,P = 0.0025,r = 0.41;白蛋白与血浆COP,P < 0.0001,r = 0.66)。
本研究猫群体中全血和血浆COP均值之间未发现显著差异。尽管无统计学意义,但配对的全血COP和血浆COP评估确实显示出轻微差异;因此,对于猫的系列评估保持样本一致性似乎是谨慎的做法。