Suppr超能文献

相似文献

1
Flow-diverter stent for the treatment of a non-origin posterior inferior cerebellar artery aneurysm. A case report.
Neuroradiol J. 2014 Sep;27(4):456-60. doi: 10.15274/NRJ-2014-10061. Epub 2014 Aug 29.
2
Clip reconstruction for a case of peripheral posterior inferior cerebellar artery aneurysm: case report.
Minim Invasive Neurosurg. 2005 Aug;48(4):244-6. doi: 10.1055/s-2005-870902.
3
Coiling for a saccular aneurysm on the caudal channel in double origin of the posterior inferior cerebellar artery.
Neuroradiol J. 2020 Aug;33(4):334-339. doi: 10.1177/1971400920910644. Epub 2020 Mar 12.
6
Treatment of a ruptured aneurysm involved in a double origin of the posterior inferior cerebellar artery.
Interv Neuroradiol. 2015 Aug;21(4):451-5. doi: 10.1177/1591019915590363. Epub 2015 Jun 25.
7
Flow diverter devices in ruptured intracranial aneurysms: a single-center experience.
J Neurosurg. 2018 Apr;128(4):1037-1043. doi: 10.3171/2016.11.JNS161937. Epub 2017 Apr 7.
8
Ten years of experience in endovascular treatment of ruptured aneurysms of the posterior inferior cerebellar artery.
Interv Neuroradiol. 2016 Apr;22(2):129-37. doi: 10.1177/1591019915622164. Epub 2016 Jan 28.
9
Aneurysm of the posterior inferior cerebellar arteries/communicating artery.
Cerebrovasc Dis. 2001;12(3):276-9. doi: 10.1159/000047716.

引用本文的文献

2
Endovascular treatment of posterior inferior cerebellar artery trunk aneurysm.
Acta Neurol Belg. 2022 Dec;122(6):1405-1417. doi: 10.1007/s13760-021-01826-8. Epub 2021 Oct 22.
3
Endovascular treatment of distal posterior inferior cerebellar artery aneurysms.
Neurosciences (Riyadh). 2016 Jul;21(3):236-40. doi: 10.17712/nsj.2016.3.20160076.

本文引用的文献

1
The SILK flow diverter in the treatment of intracranial aneurysms.
J Clin Neurosci. 2014 Feb;21(2):203-6. doi: 10.1016/j.jocn.2013.07.006. Epub 2013 Oct 13.
2
Bilateral Approach for Stent-assisted Coiling of Posterior Inferior Cerebellar Artery Aneurysms - Two Cases.
J Cerebrovasc Endovasc Neurosurg. 2012 Sep;14(3):223-7. doi: 10.7461/jcen.2012.14.3.223. Epub 2012 Sep 28.
3
Retrograde stent placement for coil embolization of a wide-necked posterior inferior cerebellar artery aneurysm.
Korean J Radiol. 2012 Jul-Aug;13(4):510-4. doi: 10.3348/kjr.2012.13.4.510. Epub 2012 Jun 18.
4
Flow-diverter silk stent for the treatment of intracranial aneurysms: 1-year follow-up in a multicenter study.
AJNR Am J Neuroradiol. 2012 Jun;33(6):1150-5. doi: 10.3174/ajnr.A2907. Epub 2012 Feb 2.
5
Flow diverters at and beyond the level of the circle of willis for the treatment of intracranial aneurysms.
Stroke. 2012 Apr;43(4):1032-8. doi: 10.1161/STROKEAHA.111.636019. Epub 2012 Jan 26.
6
Stenting from the vertebral artery to the posterior inferior cerebellar artery.
AJNR Am J Neuroradiol. 2012 Feb;33(2):348-52. doi: 10.3174/ajnr.A2741. Epub 2011 Nov 3.
8
Flow diverters for treatment of intracranial aneurysms: current status and ongoing clinical trials.
J Clin Neurosci. 2011 Jun;18(6):737-40. doi: 10.1016/j.jocn.2010.10.011. Epub 2011 Apr 21.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验