Suppr超能文献

[日本医学物理学会12应用的交叉校准束流质量转换因子的不确定性]

[Uncertainty of cross calibration-applied beam quality conversion factor for the Japan Society of Medical Physics 12].

作者信息

Kinoshita Naoki, Kita Akinobu, Takemura Akihiro, Nishimoto Yasuhiro, Adachi Toshiki

机构信息

Department of Radiology, University of Fukui Hospital.

出版信息

Nihon Hoshasen Gijutsu Gakkai Zasshi. 2014 Sep;70(9):877-82. doi: 10.6009/jjrt.2014_jsrt_70.9.877.

Abstract

The uncertainty of the beam quality conversion factor (k(Q,Q0)) of standard dosimetry of absorbed dose to water in external beam radiotherapy 12 (JSMP12) is determined by combining the uncertainty of each beam quality conversion factor calculated for each type of ionization chamber. However, there is no guarantee that ionization chambers of the same type have the same structure and thickness, so there may be individual variations. We evaluated the uncertainty of k(Q,Q0) for JSMP12 using an ionization chamber dosimeter and linear accelerator without a specific device or technique in consideration of the individual variation of ionization chambers and in clinical radiation field. The cross calibration formula was modified and the beam quality conversion factor for the experimental values [(k(Q,Q0))field] determined using the modified formula. It's uncertainty was calculated to be 1.9%. The differences between (k(Q,Q0))field of experimental values and k(Q,Q0) for Japan Society of Medical Physics 12 (JSMP12) were 0.73% and 0.88% for 6- and 10-MV photon beams, respectively, remaining within ± 1.9%. This showed k(Q,Q0) for JSMP12 to be consistent with (k(Q,Q0))field of experimental values within the estimated uncertainty range. Although inter-individual differences may be generated, even when the same type of ionized chamber is used, k(Q,Q0) for JSMP12 appears to be consistent within the estimated uncertainty range of (k(Q,Q0)field.

摘要

外照射放疗中吸收剂量到水的标准剂量学中射束质转换因子(k(Q,Q0))的不确定度,是通过将为每种电离室计算的每个射束质转换因子的不确定度进行合成来确定的。然而,无法保证同一类型的电离室具有相同的结构和厚度,所以可能存在个体差异。我们在考虑电离室个体差异及临床辐射野的情况下,使用电离室剂量仪和直线加速器,在没有特定装置或技术的情况下评估了JSMP12中k(Q,Q0)的不确定度。对交叉校准公式进行了修正,并使用修正后的公式确定了实验值的射束质转换因子[(k(Q,Q0))field]。计算得出其不确定度为1.9%。对于6兆伏和10兆伏光子束,实验值的(k(Q,Q0))field与日本医学物理学会12(JSMP12)的k(Q,Q0)之间的差异分别为0.73%和0.88%,均在±1.9%以内。这表明在估计的不确定度范围内,JSMP12的k(Q,Q0)与实验值的(k(Q,Q0))field一致。尽管即使使用同一类型的电离室也可能产生个体间差异,但在(k(Q,Q0)field的估计不确定度范围内,JSMP12的k(Q,Q0)似乎是一致的。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验