比较富尔顿高级平衡量表与 Mini-BESTest 和 Berg 平衡量表,以评估帕金森病患者的姿势控制。
Comparing the Fullerton Advanced Balance Scale with the Mini-BESTest and Berg Balance Scale to assess postural control in patients with Parkinson disease.
机构信息
Department of Neurology, Christian-Albrechts-University, Kiel, Germany; Department of Sport Science, Christian-Albrechts-University, Kiel, Germany.
Department of Neurology, Christian-Albrechts-University, Kiel, Germany.
出版信息
Arch Phys Med Rehabil. 2015 Feb;96(2):218-25. doi: 10.1016/j.apmr.2014.09.002. Epub 2014 Sep 28.
OBJECTIVES
To validate the Fullerton Advanced Balance (FAB) Scale for patients with idiopathic Parkinson disease (PD); and to compare the FAB Scale with the Mini-Balance Evaluation Systems Test (Mini-BESTest) and Berg Balance Scale (BBS).
DESIGN
Observational study to assess concurrent validity, test-retest, and interrater reliability of the FAB Scale in patients with PD and to compare the distribution of the scale with the Mini-BESTest and BBS.
SETTING
University hospital in an urban community.
PARTICIPANTS
Patients with idiopathic PD (N=85; Hoehn and Yahr stages 1-4).
INTERVENTIONS
Not applicable.
MAIN OUTCOME MEASURES
FAB Scale, Mini-BESTest, BBS, timed Up and Go test, Unified Parkinson's Disease Rating Scale, and visual analog scale.
RESULTS
Interrater (3 raters) and test-retest (3±1 d) reliability were high for all scales (ICCs≥.95). The FAB Scale was highly correlated with the Mini-BESTest (Spearman ρ=.87) and timed Up and Go test item of the Mini-BESTest (Spearman ρ=.83). In contrast with the BBS, the FAB Scale and Mini-BESTest have only minimal ceiling effects. The FAB Scale demonstrated the most symmetric distribution when compared with the Mini-BESTest and BBS (skewness: FAB scale: -.54; Mini-BESTest: -1.07; BBS: -2.14).
CONCLUSIONS
The FAB Scale is a valid and reliable tool to assess postural control in patients with PD. No ceiling effect was noted for the FAB Scale. Although the items of the FAB Scale are more detailed when compared with the Mini-BESTest, interrater and test-retest reliability were excellent. The scale is a promising tool to detect small changes of the postural control system in individuals with PD.
目的
验证特伦顿优势平衡量表(FAB)在特发性帕金森病(PD)患者中的有效性;并将 FAB 量表与简易平衡评估系统测试(Mini-BESTest)和 Berg 平衡量表(BBS)进行比较。
设计
评估 PD 患者 FAB 量表的同时效度、重测信度和评分者间信度的观察性研究,并比较该量表的分布与 Mini-BESTest 和 BBS 的分布。
地点
城市社区的大学医院。
参与者
特发性 PD 患者(N=85;Hoehn 和 Yahr 分期 1-4 级)。
干预措施
不适用。
主要观察指标
FAB 量表、Mini-BESTest、BBS、起立-行走计时测试、统一帕金森病评定量表和视觉模拟评分。
结果
所有量表的评分者间(3 名评分者)和重测信度(3±1 天)均较高(ICC≥.95)。FAB 量表与 Mini-BESTest 高度相关(Spearman ρ=.87),与 Mini-BESTest 的起立-行走计时测试项目也高度相关(Spearman ρ=.83)。与 BBS 相比,FAB 量表和 Mini-BESTest 的天花板效应最小。与 Mini-BESTest 和 BBS 相比,FAB 量表的分布更为对称(偏度:FAB 量表:-.54;Mini-BESTest:-1.07;BBS:-2.14)。
结论
FAB 量表是评估 PD 患者姿势控制的有效且可靠的工具。FAB 量表未出现天花板效应。尽管与 Mini-BESTest 相比,FAB 量表的项目更为详细,但评分者间和重测信度均极佳。该量表是检测 PD 患者姿势控制系统微小变化的有前途的工具。