Suppr超能文献

对于被动散射质子,平滑补偿器设计与插入式补偿器设计相比是否具有临床益处?

Is there a clinical benefit with a smooth compensator design compared with a plunged compensator design for passive scattered protons?

作者信息

Tabibian Art A, Powers Adam, Dolormente Keith, Oommen Sneha, Tiwari Akhil, Palmer Matt, Zhu Xiaorong R, Li Heng, Sahoo Narayan, Wisdom Paul, Velasco Kyle, Erhart Kevin, Stanley Henry, Nguyen Bao-Ngoc T

机构信息

University of Texas School of Allied Health-Medical Dosimetry, Houston, TX.

University of Texas School of Allied Health-Medical Dosimetry, Houston, TX.

出版信息

Med Dosim. 2015 Spring;40(1):37-43. doi: 10.1016/j.meddos.2014.07.004. Epub 2014 Sep 26.

Abstract

In proton therapy, passive scattered proton plans use compensators to conform the dose to the distal surface of the planning volume. These devices are custom made from acrylic or wax for each treatment field using either a plunge-drilled or smooth-milled compensator design. The purpose of this study was to investigate if there is a clinical benefit of generating passive scattered proton radiation treatment plans with the smooth compensator design. We generated 4 plans with different techniques using the smooth compensators. We chose 5 sites and 5 patients for each site for the range of dosimetric effects to show adequate sample. The plans were compared and evaluated using multicriteria (MCA) plan quality metrics for plan assessment and comparison using the Quality Reports [EMR] technology by Canis Lupus LLC. The average absolute difference for dosimetric metrics from the plunged-depth plan ranged from -4.7 to +3.0 and the average absolute performance results ranged from -6.6% to +3%. The manually edited smooth compensator plan yielded the best dosimetric metric, +3.0, and performance, + 3.0% compared to the plunged-depth plan. It was also superior to the other smooth compensator plans. Our results indicate that there are multiple approaches to achieve plans with smooth compensators similar to the plunged-depth plans. The smooth compensators with manual compensator edits yielded equal or better target coverage and normal tissue (NT) doses compared with the other smooth compensator techniques. Further studies are under investigation to evaluate the robustness of the smooth compensator design.

摘要

在质子治疗中,被动散射质子计划使用补偿器使剂量与计划靶区的远端表面相匹配。这些装置是针对每个治疗野,使用丙烯酸或蜡通过钻孔或平滑铣削补偿器设计定制而成。本研究的目的是调查采用平滑补偿器设计生成被动散射质子放射治疗计划是否具有临床益处。我们使用平滑补偿器通过不同技术生成了4个计划。我们选择了5个部位,每个部位选择5名患者,以展示剂量学效应范围从而获得足够的样本。使用多标准(MCA)计划质量指标对这些计划进行比较和评估,以通过Canis Lupus LLC公司的质量报告[EMR]技术进行计划评估和比较。与钻孔深度计划相比,剂量学指标的平均绝对差值在-4.7至+3.0之间,平均绝对性能结果在-6.6%至+3%之间。与钻孔深度计划相比,手动编辑的平滑补偿器计划产生了最佳的剂量学指标,为+3.0,以及最佳的性能,为+3.0%。它也优于其他平滑补偿器计划。我们的结果表明,有多种方法可以实现与钻孔深度计划类似的平滑补偿器计划。与其他平滑补偿器技术相比,经过手动补偿器编辑的平滑补偿器在靶区覆盖和正常组织(NT)剂量方面产生了相同或更好的效果。正在进行进一步的研究以评估平滑补偿器设计的稳健性。