Interventional Neuroradiology Unit, Service of Neuroradiology, University Hospitals of Geneva, Geneva, Switzerland Division of Neuroradiology, Department of Medical Imaging, Toronto Western Hospital, University Health Network, Toronto, Ontario, Canada Division of Neurosurgery, Department of Surgery, Toronto Western Hospital, University Health Network, Toronto, Ontario, Canada.

Division of Neurosurgery, Department of Surgery, College of Medicine, University of Saskatchewan, Saskatoon, Canada.

出版信息

J Neurointerv Surg. 2015 Dec;7(12):920-5. doi: 10.1136/neurintsurg-2014-011347. Epub 2014 Oct 3.

Abstract

BACKGROUND

Flow diverter stents (FDS) have been described as a breakthrough in the treatment of intracranial aneurysms. Of the various flow diverter models, the Pipeline device has been the main approved and used device, with established and good long-term results.

OBJECTIVE

To present the first series of patients treated with its new version, the Pipeline Flex device. This has kept the same device design and configuration but redesigned and completely modified the delivery system.

METHODS

In this technical report, we include 10 consecutive patients harboring 12 saccular aneurysms of the anterior circulation. We report the main changes on the system, immediate results, and technical nuances with illustrative cases.

RESULTS

We implanted 12 devices, including 11 Pipeline Flex and one Pipeline device. We used the old version in one case that required a second layer with a short length not available in the Pipeline Flex size range. All attempts at treatment were successful and no device was discharged or removed. Recovery was required or used in half of the cases with good or excellent performance, except in one case that presented with multiple proximal loops and tight curves. We had two transitory events without ischemic lesions on MRI that recovered 1 and 4 h after all patients were discharged home asymptomatic.

CONCLUSIONS

Pipeline Flex represents a major advance in FDS technology. The redesigned system has significantly improved the deployment of the Pipeline stent, by enabling the operator to resheath the device. It has the potential to continue revolutionizing the endovascular approach for intracranial aneurysms.

摘要

背景

血流导向支架(FDS)被认为是颅内动脉瘤治疗的一项突破。在各种血流导向模型中,Pipeline装置是主要获批并使用的装置,具有确切且良好的长期效果。

目的

介绍首例使用其新版本Pipeline Flex装置治疗的患者系列。该装置保持了相同的设计和配置,但对输送系统进行了重新设计和全面改进。

方法

在本技术报告中,我们纳入了10例连续患者,这些患者共患有12个前循环囊状动脉瘤。我们报告了该系统的主要变化、即刻结果以及通过实例说明的技术细节。

结果

我们植入了12枚装置,其中包括11枚Pipeline Flex装置和1枚Pipeline装置。在1例需要第二层且其短长度不在Pipeline Flex尺寸范围内的病例中,我们使用了旧版本。所有治疗尝试均成功,没有装置被取出或移除。半数病例需要恢复或使用,恢复情况良好或极佳,只有1例出现多个近端袢和紧密弯曲。我们有2例短暂事件,MRI显示无缺血性病变,所有患者出院回家时无症状,分别在1小时和4小时后恢复。

结论

Pipeline Flex代表了血流导向支架技术的重大进展。重新设计的系统显著改善了Pipeline支架的部署,使操作者能够将装置重新收回鞘内。它有可能继续彻底改变颅内动脉瘤的血管内治疗方法。