采用低温蒸发进样电热蒸发电感耦合等离子体质谱法测定药用活性炭中的微量元素。

Determination of trace elements in medicinal activated charcoal using slurry sampling electrothermal vaporization inductively coupled plasma mass spectrometry with low vaporization temperature.

机构信息

Department of Chemistry, National Sun Yat-sen University, Kaohsiung 80424, Taiwan.

Department of Chemistry, National Sun Yat-sen University, Kaohsiung 80424, Taiwan; Department of Medical Laboratory Science and Biotechnology, Kaohsiung Medical University, Kaohsiung 80708, Taiwan.

出版信息

Talanta. 2015 Jan;131:585-9. doi: 10.1016/j.talanta.2014.08.034. Epub 2014 Aug 22.

Abstract

The determination of Cd, Sb, Te, Hg, Tl and Pb in medicinal activated charcoal by ultrasonic slurry sampling electrothermal vaporization inductively coupled plasma mass spectrometry (USS-ETV-ICP-MS) was described. EDTA was used as the modifier to enhance the volatility of elements studied. The influences of instrument operating conditions and slurry preparation on the ion signals were studied. A relatively low vaporization temperature of 1000°C was used, which separated the analyte from the major matrix components that improved ion signals. The method has been applied to determine Cd, Sb, Te, Hg, Tl and Pb in an NIST SRM 1633b Coal Fly Ash reference material and three brands of medicinal activated charcoal capsules using isotope dilution and standard addition calibration methods. The concentrations that are in ng g(-1) levels were in good agreement between different calibration methods. The precision between sample replicates was better than 7% with USS-ETV-ICP-MS technique. The method detection limit estimated from standard addition curves was 0.4, 0.3, 0.3, 0.3, 0.04 and 0.9 ng g(-1) for Cd, Sb, Te, Hg, Tl and Pb, respectively, in original medicinal activated charcoal.

摘要

采用超声溶液进样电热蒸发电感耦合等离子体质谱法(USS-ETV-ICP-MS)测定药用活性炭中 Cd、Sb、Te、Hg、Tl 和 Pb。采用 EDTA 作为改进剂来增强研究元素的挥发性。研究了仪器操作条件和悬浮液制备对离子信号的影响。采用相对较低的 1000°C 蒸发温度,使分析物与主要基质成分分离,从而提高了离子信号。该方法已应用于使用同位素稀释和标准加入校准方法测定 NIST SRM 1633b 煤飞灰标准物质和三种品牌药用活性炭胶囊中的 Cd、Sb、Te、Hg、Tl 和 Pb。不同校准方法之间的浓度在 ng g(-1)水平上具有良好的一致性。使用 USS-ETV-ICP-MS 技术,样品重复之间的精密度优于 7%。从标准加入曲线估计的方法检测限分别为 0.4、0.3、0.3、0.3、0.04 和 0.9 ng g(-1),用于原始药用活性炭中的 Cd、Sb、Te、Hg、Tl 和 Pb。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验