Rao Roopa S, Patil Shankargouda, Agarwal Anveeta
Professor and Head, Department of Oral Pathology, MS Ramaiah Dental College Bengaluru, Karnataka, India e-mail:
Associate Professor, Department of Oral Pathology and Microbiology, Faculty of Dental Sciences, MS Ramaiah University of Applied Sciences Bengaluru, Karnataka, India.
J Contemp Dent Pract. 2014 May 1;15(3):273-7. doi: 10.5005/jp-journals-10024-1527.
Routine staining procedures often pose a problem in differentiating a mitotic cell from an apoptotic cell, deteriorating the reliability of histology grading. Although various new methods have been recommended for identifying mitotic figures (MFs) in tissues, the time factor and cost makes them less feasible. Thus, an attempt was made to evaluate the efficacy of crystal violet and Feulgen reaction in identifying MFs and also to see for any variation in the number of MFs in various grades of Epithelial dysplasia.
The study sample includes retrieval of 30 formalin fixed paraffin embedded tissue sections diagnosed for different grades of epithelial dysplasia (WHO grading system, 2005) from the archives, Department of Oral Pathology, MSRDC, Bengaluru. Ten tissue sections each of mild, moderate and severe epithelial dysplasia were stained with H&E, Feulgen and 1% crystal violet stains and the number of MFs were counted. Five cases of cervical carcinoma were taken as control. Stained sections were compared, and data obtained was statistically analyzed using the Kruskal-Wallis test.
A significant increase in the number of MFs (p = 0.02) was observed in Feulgen stained sections as compared to H&E stain.
Feulgen stain can be considered as a simple, reliable, cost-effective and reproducible method of staining MFs.
常规染色程序在区分有丝分裂细胞和凋亡细胞时常常存在问题,降低了组织学分级的可靠性。尽管已经推荐了各种新方法来识别组织中的有丝分裂象(MFs),但时间因素和成本使它们不太可行。因此,尝试评估结晶紫和福尔根反应在识别MFs方面的效果,并观察不同等级上皮发育异常中MFs数量的任何变化。
研究样本包括从班加罗尔MSRDC口腔病理学系档案中检索30例经福尔马林固定石蜡包埋的组织切片,这些切片被诊断为不同等级的上皮发育异常(WHO分级系统,2005年)。轻度、中度和重度上皮发育异常的组织切片各10例,分别用苏木精-伊红(H&E)、福尔根和1%结晶紫染色,并计数MFs的数量。选取5例宫颈癌病例作为对照。对染色切片进行比较,并使用Kruskal-Wallis检验对获得的数据进行统计分析。
与H&E染色相比,福尔根染色切片中观察到MFs数量显著增加(p = 0.02)。
福尔根染色可被视为一种简单、可靠、经济高效且可重复的MFs染色方法。