A comparison of the fitting accuracy of thermoplastic denture base resins used in non-metal clasp dentures to a conventional heat-cured acrylic resin.

作者信息

Wada Junichiro, Fueki Kenji, Yatabe Masaru, Takahashi Hidekazu, Wakabayashi Noriyuki

机构信息

Section of Removable Partial Prosthodontics, Department of Masticatory Function Rehabilitation, Graduate School of Medical and Dental Sciences.

出版信息

Acta Odontol Scand. 2015 Jan;73(1):33-7. doi: 10.3109/00016357.2014.946966. Epub 2014 Oct 14.

Abstract

OBJECTIVE

To incorporate a metal framework into removable partial dentures, the dimensional accuracy of thermoplastic resins requires precision equivalent to conventional acrylic resins. This study aimed to evaluate the fitting accuracy of thermoplastic resins compared to heat-cured acrylic resin.

MATERIALS AND METHODS

Four thermoplastic resins (polyethylene terephthalate [EstheShot, ES; EstheShot Bright, ES-B], polyamide [Lucitone FRS, LF], polycarbonate [Reigning Resin N, RN] and a heat-curing acrylic resin [Acron, AC]) were used. The specimens were created on master casts constructed of high-strength stone that simulated a maxillary edentulous ridge. Additionally, high-expansion stone was used as the master cast for RN specimens. The ES-B, LF and RN specimens were prepared with and without annealing after injection molding. The gaps between the molded resin and the cast were measured.

RESULTS

ES had the smallest gap and was significantly smaller than AC (p < 0.05). The gap sizes of ES-B, LF and RN (high-expansion stone) without annealing were similar to AC (p > 0.05), while the gap size of RN (high-strength stone) with and without annealing was significantly greater than AC (p < 0.001). The gap sizes of ES-B and LF with annealing were significantly less than AC (p < 0.05). Further, the gap sizes of ES-B, LF and RN with annealing were significantly smaller than the gaps without annealing (p < 0.05).

CONCLUSIONS

The results suggested that ES, ES-B and LF have adequate fitting accuracy for incorporating metal framework into dentures and that annealing effectively improved the fitting accuracy of ES-B, LF and RN.

摘要

目的

为了将金属框架纳入可摘局部义齿,热塑性树脂的尺寸精度需要与传统丙烯酸树脂相当的精度。本研究旨在评估热塑性树脂与热固化丙烯酸树脂相比的贴合精度。

材料与方法

使用了四种热塑性树脂(聚对苯二甲酸乙二酯[EstheShot,ES;EstheShot Bright,ES - B]、聚酰胺[Lucitone FRS,LF]、聚碳酸酯[Reigning Resin N,RN])和一种热固化丙烯酸树脂[Acron,AC]。标本在由模拟上颌无牙嵴的高强度石膏制成的主模型上制作。此外,高膨胀石膏用作RN标本的主模型。ES - B、LF和RN标本在注塑成型后进行了退火和未退火处理。测量成型树脂与模型之间的间隙。

结果

ES的间隙最小,且明显小于AC(p < 0.05)。未退火的ES - B、LF和RN(高膨胀石膏)的间隙尺寸与AC相似(p > 0.05),而退火和未退火的RN(高强度石膏)的间隙尺寸明显大于AC(p < 0.001)。退火后的ES - B和LF的间隙尺寸明显小于AC(p < 0.05)。此外,退火后的ES - B、LF和RN的间隙尺寸明显小于未退火的间隙(p < 0.05)。

结论

结果表明,ES、ES - B和LF对于将金属框架纳入义齿具有足够的贴合精度,并且退火有效地提高了ES - B、LF和RN的贴合精度。