Imaging the central conducting lymphatics: initial experience with dynamic MR lymphangiography.

机构信息

From the EB Singleton Department of Pediatric Radiology, Texas Children's Hospital, Baylor College of Medicine, 6701 Fannin St, Suite 1280, Houston, TX 77030.

出版信息

Radiology. 2015 Mar;274(3):871-8. doi: 10.1148/radiol.14131399. Epub 2014 Oct 15.

Abstract

PURPOSE

To describe a dynamic magnetic resonance (MR) lymphangiography technique after intranodal injection of gadolinium-based contrast agent and to assess its feasibility for evaluation of the central conducting lymphatics (CCL) in patients with pathologic disorders that involve the CCL.

MATERIALS AND METHODS

A retrospective evaluation of experience with the dynamic MR lymphangiographic technique in six consecutive patients was performed after institutional review board approval. Written informed consent for the percutaneous procedure was obtained from the patient, parent, or the legally responsible guardian. The dynamic MR lymphangiographic technique involves ultrasonographically guided intranodal injection of gadolinium-based contrast material into the inguinal lymph nodes, combined with sequential imaging of the chest and abdomen with a three-dimensional sequence optimized for soft tissue with high spatial resolution that provides time-resolved imaging of lymphatic transit through the CCL. Qualitative assessment of the images was performed for reliability of CCL visualization and for associated findings that could explain the clinical symptoms, including lymphangiectasia, chylolymphatic reflux, and chylous leak.

RESULTS

The procedure was technically successful in all six patients. The dynamic MR lymphangiographic findings confirmed the presence of normal CCL morphologic structure in two patients and provided a possible explanation for clinical manifestations in the remaining four patients. The dynamic MR lymphangiographic procedure led to a change in management in two patients, continuation of conservative treatment in three patients, and confirmation of an alternative nonlymphatic diagnosis in one patient. Image quality for visualization of the CCL was considered good in all cases by the two readers. There were no known adverse effects related to the procedure.

CONCLUSION

The dynamic MR lymphangiographic technique with intranodal injection of gadolinium-based contrast material is feasible and can provide useful information in a variety of lymphatic flow abnormalities involving the CCL.

摘要

目的

描述一种经皮节点内注射钆基对比剂后动态磁共振(MR)淋巴造影技术,并评估其在涉及中央导淋巴管(CCL)的病理疾病患者中评估中央导淋巴管的可行性。

材料与方法

在机构审查委员会批准后,对连续 6 例患者的动态 MR 淋巴造影技术经验进行了回顾性评估。患者、父母或法定监护人书面同意进行经皮程序。动态 MR 淋巴造影技术包括超声引导下经节点内注射钆基对比剂到腹股沟淋巴结,结合胸部和腹部的三维序列进行连续成像,该序列优化用于软组织,具有高空间分辨率,可提供淋巴通过 CCL 的时间分辨成像。对图像进行定性评估,以评估 CCL 可视化的可靠性和可能解释临床症状的相关发现,包括淋巴管扩张、乳糜淋巴反流和乳糜漏。

结果

该程序在所有 6 例患者中均成功完成。动态 MR 淋巴造影结果在 2 例患者中证实了 CCL 形态结构正常,并为其余 4 例患者的临床表现提供了可能的解释。动态 MR 淋巴造影程序导致 2 例患者的治疗方式发生改变,3 例患者继续保守治疗,1 例患者确认了另一种非淋巴诊断。两位读者均认为,所有病例的 CCL 可视化图像质量均良好。没有与该程序相关的已知不良影响。

结论

经节点内注射钆基对比剂的动态 MR 淋巴造影技术是可行的,并且可以在涉及 CCL 的各种淋巴流异常中提供有用的信息。