Schwarz Christina, Manzanera Silvestre, Prieto Pedro M, Fernández Enrique J, Artal Pablo
Laboratorio de Óptica, Instituto Universitario de Investigación en Óptica y Nanofísica, Universidad de Murcia, Campus de Espinardo (Edificio 34), 30100 Murcia, Spain.
Biomed Opt Express. 2014 Sep 2;5(10):3355-66. doi: 10.1364/BOE.5.003355. eCollection 2014 Oct 1.
Corneal small aperture inlays provide extended depth of focus as a solution to presbyopia. As this procedure is becoming more popular, it is interesting to compare its performance with traditional approaches, such as monovision. Here, binocular visual acuity was measured as a function of object vergence in three subjects by using a binocular adaptive optics vision analyzer. Visual acuity was measured at two luminance levels (photopic and mesopic) under several optical conditions: 1) natural vision (4 mm pupils, best corrected distance vision), 2) pure-defocus monovision ( + 1.25 D add in the nondominant eye), 3) small aperture monovision (1.6 mm pupil in the nondominant eye), and 4) combined small aperture and defocus monovision (1.6 mm pupil and a + 0.75 D add in the nondominant eye). Visual simulations of a small aperture corneal inlay suggest that the device extends DOF as effectively as traditional monovision in photopic light, in both cases at the cost of binocular summation. However, individual factors, such as aperture centration or sensitivity to mesopic conditions should be considered to assure adequate visual outcomes.
角膜小孔植入物可提供扩展焦深,作为老花眼的一种解决方案。随着这种手术越来越受欢迎,将其性能与传统方法(如单眼视力矫正)进行比较很有意思。在此,通过使用双目自适应光学视觉分析仪,测量了三名受试者的双目视力随物距变化的情况。在几种光学条件下,于两种亮度水平(明视觉和中间视觉)下测量视力:1)自然视力(4毫米瞳孔,最佳矫正远视力),2)单纯散焦单眼视力矫正(非优势眼加 +1.25 D),3)小孔单眼视力矫正(非优势眼瞳孔为1.6毫米),以及4)小孔与散焦联合单眼视力矫正(非优势眼瞳孔为1.6毫米且加 +0.75 D)。小孔角膜植入物的视觉模拟表明,在明视觉下,该装置扩展焦深的效果与传统单眼视力矫正一样有效,在这两种情况下都以双目总和为代价。然而,应考虑个体因素,如孔径对中或对中间视觉条件的敏感度,以确保获得足够的视觉效果。