Suppr超能文献

阅读性能和患者满意度后角膜镶嵌植入术治疗老视矫正:两年的随访。

Reading performance and patient satisfaction after corneal inlay implantation for presbyopia correction: two-year follow-up.

机构信息

Department of Ophthalmology, Paracelsus Medical University, Salzburg, Austria.

出版信息

J Cataract Refract Surg. 2012 Oct;38(10):1808-16. doi: 10.1016/j.jcrs.2012.06.047. Epub 2012 Aug 22.

Abstract

PURPOSE

To evaluate change in reading performance parameters after monocular Kamra corneal inlay implantation for the surgical correction of presbyopia.

SETTING

University surgical outpatient center.

DESIGN

Prospective interventional case series.

METHODS

A corneal inlay was implanted in the nondominant eye. Naturally emmetropic and presbyopic patients between 45 years and 60 years old with an uncorrected distance visual acuity of at least 20/20 in both eyes without additional ocular pathology were eligible for inclusion. Bilateral uncorrected reading acuity, reading distance, mean and maximum reading speed, and the smallest log-scaled print size (lower case letter of a Radner reading chart) were evaluated using the Salzburg Reading Desk. The minimum postoperative follow-up was 24 months.

RESULTS

Twenty-four patients were enrolled. The mean reading distance was 46.7 cm ± 6.3 (SD) preoperatively and 39.5 ± 6.4 cm 24 months postoperatively (P<.001). The mean reading acuity at best distance improved (0.33 ± 0.13 logRAD versus 0.23 ± 0.11 logRAD) (P=.004). The mean reading speed increased from 141 ± 20 words per minute (wpm) to 146 ± 20 wpm, respectively (P=.261), and the mean maximum reading speed from 171 ± 28 wpm to 180 ± 22 wpm, respectively (P=.110). The smallest print size improved from 1.50 ± 0.42 mm to 1.01 ± 0.22 mm, respectively (P<.001).

CONCLUSION

Improving the depth of focus by monocular implantation of a small-aperture optic caused statistically significant changes in all tested reading performance parameters except reading speed metrics in emmetropic presbyopic patients.

摘要

目的

评估单眼 Kamra 角膜镶嵌术治疗老视的手术矫正后阅读性能参数的变化。

设置

大学门诊手术中心。

设计

前瞻性干预性病例系列。

方法

在非主导眼植入角膜镶嵌片。符合条件的患者为 45 岁至 60 岁之间的自然正视和老视患者,双眼未矫正远视力至少为 20/20,无其他眼部疾病。使用萨尔茨堡阅读台评估双眼未矫正阅读视力、阅读距离、平均和最大阅读速度以及最小对数标度打印尺寸(Radner 阅读图表的小写字母)。术后最短随访时间为 24 个月。

结果

共纳入 24 例患者。术前平均阅读距离为 46.7cm±6.3(SD),术后 24 个月为 39.5cm±6.4cm(P<.001)。最佳距离阅读视力提高(0.33±0.13 logRAD 与 0.23±0.11 logRAD)(P=.004)。阅读速度从 141±20 个单词每分钟(wpm)提高到 146±20 wpm,分别为(P=.261),最大阅读速度从 171±28 wpm 提高到 180±22 wpm,分别为(P=.110)。最小打印尺寸从 1.50±0.42mm 提高到 1.01±0.22mm,分别为(P<.001)。

结论

通过单眼植入小孔径光学器件增加景深,在所有测试的阅读性能参数中除阅读速度外均引起统计学显著变化,在正视性老视患者中。