Suppr超能文献

根管预备对使用GuttaCore充填的直根管充填长度的影响。

The effect of canal preparation on fill length in straight root canals obturated with GuttaCore.

作者信息

Whitten Robert B, Levitan Marc E

机构信息

Medical University of South Carolina, Charleston, South Carolina.

Medical University of South Carolina, Charleston, South Carolina.

出版信息

J Endod. 2015 Feb;41(2):155-8. doi: 10.1016/j.joen.2014.09.020. Epub 2014 Oct 30.

Abstract

INTRODUCTION

A common critique of using thermoplasticized carrier-based obturators is the incidence of overextension. It would be of benefit to clinicians to have a technique for canal preparation that would allow for predictable length control. This study compared straight canals instrumented to a size 40 file using a 0.04 standardized taper preparation (STP) and a varied taper preparation (VTP) by evaluating the extension of GuttaCore (GC) obturators (Dentsply Tulsa Dental, Tulsa, OK).

METHODS

Eighty extracted mature human premolars with single straight canals were randomly divided into 2 experimental groups (n = 40). The STP group was instrumented to size 40/.04 at the working length (WL). The VTP group was instrumented to size 40/.02 at the WL. Both groups were obturated with a size 40 GC obturator. Extension of the material, in relation to the WL, was evaluated and assessed ordinally. Statistically significant differences were determined by a 2-group chi-square test with a 2-sided P value set at P = .05 and a Fisher exact test of equal proportions.

RESULTS

Significant differences in extrusion existed between the STP and VTP groups when controlling for the type of apical preparation (P = .0005). The STP group resulted in a 47.2% incidence of overextension, whereas the VTP group resulted in 10.5% overextension of obturating material.

CONCLUSIONS

The results indicate that when filling straight canals with GC obturators the canal can be instrumented using a varied tapered canal preparation with a low likelihood of overextension.

摘要

引言

对使用热塑性载体型封闭剂的一个常见批评是超充的发生率。对于临床医生来说,拥有一种能实现可预测长度控制的根管预备技术将大有裨益。本研究通过评估GuttaCore(GC)封闭剂(登士柏图尔萨牙科公司,图尔萨,俄克拉何马州)的超充情况,比较了使用0.04标准锥度预备(STP)和可变锥度预备(VTP)将直根管预备到40号锉的情况。

方法

80颗拔除的具有单一直根管的成熟人类前磨牙被随机分为2个实验组(n = 40)。STP组在工作长度(WL)处预备到40/.04号。VTP组在WL处预备到40/.02号。两组均用40号GC封闭剂进行充填。评估并按顺序评定材料相对于WL的超充情况。通过双侧P值设定为P = .05的两组卡方检验和等比例的Fisher精确检验确定统计学上的显著差异。

结果

在控制根尖预备类型时,STP组和VTP组之间的超充存在显著差异(P = .0005)。STP组超充发生率为47.2%,而VTP组封闭材料超充率为10.5%。

结论

结果表明,当用GC封闭剂充填直根管时,可采用可变锥度的根管预备,超充可能性较低。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验