Kosse Nienke M, Caljouw Simone, Vervoort Danique, Vuillerme Nicolas, Lamoth Claudine J C
Center for Human Movement Sciences, University of Groningen, University Medical Center Groningen, Antonius Deusinglaan 1, 9713 AV, Groningen, The Netherlands,
Ann Biomed Eng. 2015 Aug;43(8):1935-46. doi: 10.1007/s10439-014-1232-0. Epub 2014 Dec 31.
Accelerometer-based assessments can identify elderly with an increased fall risk and monitor interventions. Smart devices, like the iPod Touch, with built-in accelerometers are promising for clinical gait and posture assessments due to easy use and cost-effectiveness. The aim of the present study was to establish the validity and reliability of the iPod Touch for gait and posture assessment. Sixty healthy participants (aged 18-75 years) were measured with an iPod Touch and stand-alone accelerometer while they walked under single- and dual-task conditions, and while standing in parallel and semi-tandem stance with eyes open, eyes closed and when performing a dual task. Cross-correlation values (CCV) showed high correspondence of anterior-posterior and medio-lateral signal patterns (CCV's ≥ 0.88). Validity of gait parameters (foot contacts, index of harmonicity, and amplitude variability) and standing posture parameters [root mean square of accelerations, median power frequency (MPF) and sway area] as indicated by intra-class correlation (ICC) was high (ICC = 0.85-0.99) and test-retest reliability was good (ICC = 0.81-0.97), except for MPF (ICC = 0.59-0.87). Overall, the iPod Touch obtained valid and reliable measures of gait and postural control in healthy adults of all ages under different conditions. Additionally, smart devices have the potential to be used for clinical gait and posture assessments.
基于加速度计的评估可以识别跌倒风险增加的老年人并监测干预措施。像iPod Touch这样内置加速度计的智能设备,因其使用方便且成本效益高,在临床步态和姿势评估方面颇具前景。本研究的目的是确定iPod Touch在步态和姿势评估方面的有效性和可靠性。60名健康参与者(年龄在18 - 75岁之间)在单任务和双任务条件下行走时,以及在睁眼、闭眼和平行及半串联站立姿势下执行双任务时,使用iPod Touch和独立加速度计进行测量。互相关值(CCV)显示前后和内外侧信号模式具有高度一致性(CCV≥0.88)。类内相关系数(ICC)表明步态参数(足部接触、谐波指数和幅度变异性)和站立姿势参数[加速度均方根、中位功率频率(MPF)和摆动面积]的有效性较高(ICC = 0.85 - 0.99),重测可靠性良好(ICC = 0.81 - 0.97),MPF除外(ICC = 0.59 - 0.87)。总体而言,iPod Touch在不同条件下为各年龄段健康成年人的步态和姿势控制提供了有效且可靠的测量。此外,智能设备有潜力用于临床步态和姿势评估。