Suppr超能文献

液相色谱-电喷雾串联质谱法衍生化灵敏测定人尿液中 3-羟基苯并[a]芘。

Derivatization method for sensitive determination of 3-hydroxybenzo[a]pyrene in human urine by liquid chromatography-electrospray tandem mass spectrometry.

机构信息

MOE Laboratory for Earth Surface Processes, College of Urban and Environmental Sciences, Peking University, Beijing 100871, China.

MOE Laboratory for Earth Surface Processes, College of Urban and Environmental Sciences, Peking University, Beijing 100871, China.

出版信息

J Chromatogr A. 2015 Jan 30;1379:51-5. doi: 10.1016/j.chroma.2014.12.043. Epub 2014 Dec 19.

Abstract

While urinary 3-hydroxybenzo[a]pyrene (3-OHBaP) can indicate exposure to carcinogenic benzo[a]pyrene (BaP) in humans, most previous analytical methods could not detect it in the general population due to a lack of sufficient sensitivity. In this study, a new liquid chromatography-electrospray mass-mass spectrometry (LC-ESI-MS/MS) method was developed to analyze 3-OHBaP by employing an optimized derivatization reaction with dansyl chloride (DNS) in the aqueous phase. The instrument detection limit (IDL) of the newly developed method was 10ng/L, which is 60-fold lower than without derivatization. The method was successfully applied to analyze 3-OHBaP and 1-hydroxypyrene (1-OHPy) in human urine combined with enzymatic hydrolysis, C18 enrichment, liquid-liquid extraction and silica cartridge cleanup. The overall method recoveries were 68.7±5.47% for 3-OHBaP and 72.3±4.96% for 1-OHPy, with matrix effects of <10%. The limits of quantification (LOQs) in urine were 0.3±0.02ng/L and 0.5±0.02ng/L (n=3), respectively. The method was applied to analyze seven urine samples of volunteers, and 3-OHBaP was detected in five samples. The concentration of urinary 3-OHBaP ranged from <LOD to 2.30ng/L, much lower than those (42.0-216ng/L) of 1-OHPy. The developed method provides a new way to sensitively determine 3-OHBaP in urine of the general population.

摘要

尿液中 3-羟基苯并[a]芘(3-OHBaP)可反映人体接触致癌性苯并[a]芘(BaP)的情况,但由于灵敏度不足,大多数先前的分析方法无法在普通人群中检测到。在这项研究中,我们开发了一种新的液相色谱-电喷雾串联质谱(LC-ESI-MS/MS)方法,该方法通过在水相中用丹磺酰氯(DNS)进行优化衍生化反应来分析 3-OHBaP。新方法的仪器检测限(IDL)为 10ng/L,比未衍生化时低 60 倍。该方法成功地与酶解、C18 富集、液液萃取和硅胶柱净化相结合,用于分析人尿液中的 3-OHBaP 和 1-羟基芘(1-OHPy)。3-OHBaP 和 1-OHPy 的总体方法回收率分别为 68.7±5.47%和 72.3±4.96%,基质效应<10%。尿液中的定量限(LOQs)分别为 0.3±0.02ng/L 和 0.5±0.02ng/L(n=3)。该方法应用于分析 7 名志愿者的尿液样本,其中 5 个样本检测到 3-OHBaP。尿液中 3-OHBaP 的浓度范围为<LOD 至 2.30ng/L,远低于 1-OHPy 的浓度(42.0-216ng/L)。该方法为灵敏测定普通人群尿液中 3-OHBaP 提供了一种新方法。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验