In this study, the effect of three operating parameters, i.e., the first/second volumetric feeding ratio (milliliters/milliliters), the first anaerobic/aerobic (an/oxic) time ratio (minute/minute), and the second an/oxic time ratio (minute/minute), on the performance of a two-step fed sequencing batch reactor (SBR) system to treat swine wastewater for nutrients removal was examined. Central Composite Design, coupled with Response Surface Methodology, was employed to test these parameters at five levels in order to optimize the SBR to achieve the best removal efficiencies for six response variables including total nitrogen (TN), ammonium nitrogen (NH4-N), total phosphorus (TP), dissolved phosphorus (DP), chemical oxygen demand (COD), and biochemical oxygen demand (BOD). The results showed that the three parameters investigated had significant impact on all the response variables (TN, NH4-N, TP, DP, COD, and BOD), although the highest removal efficiency for each individual responses was associated with different combination of the three parameters. The maximum TN, NH4-N, TP, DP, COD, and BOD removal efficiencies of 96.38%, 95.38%, 93.62%, 94.3%, 95.26%, and 92.84% were obtained at the optimal first/second volumetric feeding ratio, first an/oxic time ratio, and second an/oxic time ratio of 3.23, 0.4, and 0.8 for TN; 2.64, 0.72, and 0.76 for NH4-N; 3.08, 1.16, and 1.07 for TP; 1.32, 0.81, and 1.0 for DP; 2.57, 0.96, and 1.12 for COD; and 1.62, 0.64, and 1.61 for BOD, respectively. Good linear relationships between the predicted and observed results for all the response variables were observed.

摘要

在本研究中,考察了三个操作参数,即第一/第二体积进料比(毫升/毫升)、第一厌氧/好氧(缺氧/好氧)时间比(分钟/分钟)和第二缺氧/好氧时间比(分钟/分钟)对两步进水序批式反应器(SBR)系统处理猪废水以去除营养物性能的影响。采用中心复合设计结合响应面方法,在五个水平上测试这些参数,以优化SBR,实现对包括总氮(TN)、铵态氮(NH4-N)、总磷(TP)、溶解性磷(DP)、化学需氧量(COD)和生化需氧量(BOD)在内的六个响应变量的最佳去除效率。结果表明,所研究的三个参数对所有响应变量(TN、NH4-N、TP、DP、COD和BOD)均有显著影响,尽管每个单独响应的最高去除效率与这三个参数的不同组合相关。在最佳的第一/第二体积进料比、第一缺氧/好氧时间比和第二缺氧/好氧时间比分别为3.23、0.4和0.8(针对TN);2.64、0.72和0.76(针对NH4-N);3.08、1.16和1.07(针对TP);1.32、0.81和1.0(针对DP);2.57、0.96和1.12(针对COD);以及1.62、0.64和1.61(针对BOD)时,分别获得了96.38%、95.38%、93.62%、94.3%、95.26%和92.84%的最大TN、NH4-N、TP、DP、COD和BOD去除效率。观察到所有响应变量的预测结果与实测结果之间具有良好的线性关系。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验