脊柱手术中使用单极电刀对股动脉内皮的破坏作用:实验研究

Destructive effect of monopolar electrocautery knife usage on femoral artery endothelium during spine surgery: experimental study.

作者信息

Bayram Ednan, Çalik Muhammet, Atalay Canan, Aydin Mehmet Dumlu, Gundogdu Cemal, Kocaturk Hasan

机构信息

Training and Research Hospital, Department of Cardiology, Erzurum, Turkey.

Ataturk University, Faculty of Medicine, Department of Pathology, Erzurum, Turkey.

出版信息

Eurasian J Med. 2009 Aug;41(2):91-4.

Abstract

OBJECTIVE

Circulatory disorders are observed in the lower extremities of some patients after spinal surgery when a monopolar electrocautery knife (MEK) is used. Despite known the knowledge that electric currents can be hazardous to living tissues, MEK has been widely used in spine surgery. In this study, we investigated if MEK can cause endothelial injury in femoral arteries (FA).

MATERIALS AND METHODS

Eighteen rabbits were included in this study, two of which were used as the reference group. The remaining animals were subjected to paravertebral soft tissue dissection along levels L1-L4. Half of the animals were dissected with MEK, and the other half were dissected with scissors and bipolar cautery. One month after the surgery, endothelial changes of the FAs were examined stereologically.

RESULTS

Endothelial desquamation, cytoplasmic and nuclear condensations, cellular shrinkage and cellular loss were developed in the FAs of the MEK group. The endothelial cell density was 270 cells/mm2 in normal animals, 240 cells/mm2 in the non- MEK group and 190 cells/mm2 in the MEK group. The difference between the non-MEK and normal groups was not meaningful (P>0.05). The difference between the MEK and non-MEK groups was statistically significant (P<0.05); differences between the MEK and normal animals were even more significant (P<0.001).

CONCLUSION

Sharp dissection with MEK can have a detrimental effect on the endothelial cells of the FAs and cause postoperative circulatory disorders in the lower extremities. Therefore, long-term high-voltage electrocauterization should be avoided during spinal surgery unless absolutely necessary.

摘要

目的

在脊柱手术中使用单极电刀(MEK)时,部分患者的下肢会出现循环障碍。尽管已知电流对活组织有害,但MEK仍在脊柱手术中广泛使用。在本研究中,我们调查了MEK是否会导致股动脉(FA)内皮损伤。

材料与方法

本研究纳入18只兔子,其中2只作为参照组。其余动物在L1 - L4水平进行椎旁软组织解剖。一半动物用MEK进行解剖,另一半用剪刀和双极电凝进行解剖。手术后1个月,采用体视学方法检查FA的内皮变化。

结果

MEK组的FA出现内皮剥脱、细胞质和细胞核凝聚、细胞皱缩和细胞丢失。正常动物的内皮细胞密度为270个细胞/mm²,非MEK组为240个细胞/mm²,MEK组为190个细胞/mm²。非MEK组与正常组之间的差异无统计学意义(P>0.05)。MEK组与非MEK组之间的差异具有统计学意义(P<0.05);MEK组与正常动物之间的差异更显著(P<0.001)。

结论

使用MEK进行锐性解剖会对FA的内皮细胞产生有害影响,并导致下肢术后循环障碍。因此,脊柱手术中除非绝对必要,应避免长期高压电灼。

相似文献

7
[Do bipolar scissors increase postoperative adhesions? An experimental double-blind randomized trial].
Ann Chir. 2002 Nov;127(9):680-4. doi: 10.1016/s0003-3944(02)00863-5.

本文引用的文献

3
Origin and course of nerves immunoreactive for calcitonin gene-related peptide surrounding the femoral artery in rat.
Anat Embryol (Berl). 2003 Dec;207(4-5):299-305. doi: 10.1007/s00429-003-0359-9. Epub 2003 Nov 14.
5
9
Alteration in sensory nerve function following electrical shock.
Burns. 1996 Dec;22(8):602-6. doi: 10.1016/s0305-4179(96)00055-1.
10
Delayed bilateral median nerve injury due to low-tension electric current.
Neuropediatrics. 1996 Apr;27(2):105-7. doi: 10.1055/s-2007-973758.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验