OBJECTIVE

To explore the application of optimal monochromatic images according to computed tomography (CT) values of conventional CT scans with high concentration contrast agent and the feasibility in guiding abdominal arteries imaging with low concentration contrast.

METHODS

From March 2013 to February 2014, 160 patients of suspected celiac disease with a body mass index (BMI) of >25 kg/m(2) underwent spectral CT scan. And they were randomly divided into two groups. In group A (n = 61), 270 mgI/ml low concentrations of contrast agents and spectral CT imaging; in group B (n = 99), 350 mgI/ml high concentrations of contrast agents and 120 kVp scan. For CT values of the first measurement of abdominal aorta B group of patients, the average CT value was calculated . The optimal monochromatic images of group A according to CT values of group B were reconstructed and 70 keV images (group C) also reconstructed. The CT values of hepatic, splenic, right renal and superior mesenteric arteries were measured and contrast to noise ratios (CNRs) calculated. CT values and CNR were compared through t test on independent samples. P > 0.05 indicated no significant difference.

RESULTS

Mean CT value of abdominal aorta was (422 ± 65) HU in group B. And optimal keV was (67 ± 5) keV in group A. CT values of abdominal aorta and its branches showed no statistical significance; the CNRs of abdominal aorta and its branches showed statistical significance. The scoring consistency between two observers was excellent and the score (4.1 ± 0.9 vs 4.2 ± 0.7) showed no significant difference (P > 0.05).

CONCLUSION

GSI abdominal scans with low concentration contrast may obtain better image qualities compared to conventional CTA of high concentration. And (67 ± 5) keV is recommended.