Abstract

OBJECTIVE

The aim of this study was to biomechanically compare 3 different cannulated screw configurations used in internal fixation of unstable femoral neck fractures.

METHODS

The study included 28 synthetic left femurs randomly divided into 4 equal groups. Samples in the first 3 groups were osteotomized in the basicervical region to create Pauwels Type 3 fractures. Fixation was carried out using cannulated screws. In Group 1, four screws were used including 3 in an inverted triangle configuration in parallel with the neck and the fourth screw transversely into the calcar. In Group 2, three screws were used including 2 in parallel with the neck and the third transversely into the calcar. In Group 3, three screws were used in an inverted triangle configuration in parallel with the neck. No osteotomy or fixation was carried out in Group 4. Load test was performed on all the groups and the strength of the screw fixations against axial load and their amount of relocation were measured.

RESULTS

Average maximum strength was 36.1 ± 3.2 N/mm2 in Group 1, 27.3 ± 4.1 N/mm2 in Group 2 and 21.9 ± 3.2 N/mm2 in Group 3. The average relocation in the line of osteotomy in the moment of average maximum stress (21.9 ± 3.2 N/mm2) was 11.5 ± 2.1 mm in Group 3, 6 ± 1.3 mm in Group 2 and 5.8 ± 1.1 mm in Group 1 (p<0.05). It was also observed that while the relocation in the moment of average maximum stress (27.3 ± 4.1 N/mm2) was 9.1 ± 1.7 mm in Group 2, the deformation under the same stress value was 9 ± 1.7 mm in Group 1 (p>0.05).

CONCLUSION

The use of a transverse screw in the calcar in addition to cannulated screws parallel to the neck appear to provide stability benefit in the treatment of unstable femoral neck fractures.

摘要

目的

本研究旨在对用于不稳定型股骨颈骨折内固定的3种不同空心螺钉配置进行生物力学比较。

方法

本研究纳入28根合成左股骨,随机分为4组,每组数量相等。前三组样本在股骨颈基底部进行截骨,造成 Pauwels Ⅲ型骨折,使用空心螺钉进行固定。第1组使用4枚螺钉,其中3枚呈倒三角形与股骨颈平行,第4枚螺钉横向打入股骨距。第2组使用3枚螺钉,其中2枚与股骨颈平行,第3枚螺钉横向打入股骨距。第3组使用3枚螺钉呈倒三角形与股骨颈平行。第4组不进行截骨或固定。对所有组进行载荷测试,测量螺钉固定对抗轴向载荷的强度及其移位量。

结果

第1组平均最大强度为36.1±3.2N/mm²,第2组为27.3±4.1N/mm²,第3组为21.9±3.2N/mm²。在平均最大应力(21.9±3.2N/mm²)时,第3组截骨线处的平均移位为11.5±2.1mm,第2组为6±1.3mm,第1组为5.8±1.1mm(p<0.05)。还观察到,在平均最大应力(27.3±4.1N/mm²)时,第2组的移位为9.1±1.7mm,而在相同应力值下第1组的变形为9±1.7mm(p>0.05)。

结论

除了与股骨颈平行的空心螺钉外,在股骨距处使用横向螺钉似乎在治疗不稳定型股骨颈骨折中能提供稳定性优势。