• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Comparison of high resolution gradient echo, XBONE T1, XBONE T2, Spin Echo T1 and 3D SST1 magnetic resonance imaging sequences for imagining the canine elbow.

作者信息

Zhalniarovich Y, Adamiak Z, Głodek J, Przyborowska P, Holak P

出版信息

Pol J Vet Sci. 2014;17(4):587-91. doi: 10.2478/pjvs-2014-0088.

DOI:10.2478/pjvs-2014-0088
PMID:25638971
Abstract

Twenty canine elbows were examined by low-field MRI. The objective of this study was to compare five magnetic resonance sequences: High Resolution Gradient Echo in the sagittal plane, XBONE T2 in the sagittal plane, Spin Echo T1 in the sagittal plane, Spin Echo T1 in the dorsal plane and 3D SST1 and XBONE T1 in the transverse plane, and to determine which sequences have the highest diagnostic value in imagining the canine elbow. High Resolution Gradient Echo, XBONE T2 and Spin Echo T1 sequences in the sagittal plane proved to be very useful in evaluations of osseous structures such as the medial coronoid process, the anconeal process of the ulna and joint surfaces. The above sequences facilitate evaluations of radial extensor muscle of the wrist, biceps brachii muscle, triceps brachii muscle and the flexor carpi ulnaris muscle. 3D SST1 and XBONE T1 sequences in the transverse plane produce high-quality images of the medial humeral condyle and surfaces of the elbow joint. Those sequences are also useful for evaluating the surrounding muscles: extensor digitorum communis muscle, extensor carpi radialis muscle, deltoid muscle, biceps brachii muscle, pronator teres muscle and flexor carpi ulnaris muscle. The Spin Echo T1 sequence in the dorsal plane facilitates assessments of joint surfaces, medial humeral condyle, superficial digital flexor muscle, deep digital flexor muscle, triceps brachii muscle and extensor digitorum lateralis muscle. The Spin Echo T1 sequence in the sagittal plane has a short scan time, but it produces images of lower quality than High Resolution Gradient Echo and XBONE T2 sequences in the sagittal plane.

摘要

相似文献

1
Comparison of high resolution gradient echo, XBONE T1, XBONE T2, Spin Echo T1 and 3D SST1 magnetic resonance imaging sequences for imagining the canine elbow.
Pol J Vet Sci. 2014;17(4):587-91. doi: 10.2478/pjvs-2014-0088.
2
Comparison of spin echo, gradient echo and fat saturation magnetic resonance imaging sequences for imaging the canine elbow.自旋回波、梯度回波和脂肪抑制磁共振成像序列在犬肘部成像中的比较。
Vet Radiol Ultrasound. 1998 Nov-Dec;39(6):518-23. doi: 10.1111/j.1740-8261.1998.tb01642.x.
3
Effect of positioning, scan plane, and arthrography on visibility of periarticular canine shoulder soft tissue structures on magnetic resonance images.定位、扫描平面及关节造影对犬肩关节周围软组织结构在磁共振图像上可视性的影响。
Vet Radiol Ultrasound. 2008 Nov-Dec;49(6):529-39. doi: 10.1111/j.1740-8261.2008.00429.x.
4
[Anatomical observation and CT three-dimensional reconstruction of Five-shu acupoints of Shaoyin Heart Meridian in rabbit's forelimb].[兔前肢少阴心经五输穴的解剖观察与CT三维重建]
Zhen Ci Yan Jiu. 2023 Apr 25;48(4):385-91. doi: 10.13702/j.1000-0607.20220283.
5
Magnetic resonance imaging of primary and concomitant flexor enthesopathy in the canine elbow.
Vet Radiol Ultrasound. 2014 Jan-Feb;55(1):56-62. doi: 10.1111/vru.12090. Epub 2013 Aug 23.
6
Dynamic contributions of the flexor-pronator mass to elbow valgus stability.屈肌-旋前圆肌肌群对肘外翻稳定性的动态作用。
J Bone Joint Surg Am. 2004 Oct;86(10):2268-74. doi: 10.2106/00004623-200410000-00020.
7
MR imaging of the inner ear and cerebellopontine angle: comparison of three-dimensional and two-dimensional sequences.内耳及桥小脑角的磁共振成像:三维与二维序列的比较
AJR Am J Roentgenol. 1998 Mar;170(3):791-6. doi: 10.2214/ajr.170.3.9490977.
8
Anatomic study of the canine stifle using low-field magnetic resonance imaging (MRI) and MRI arthrography.使用低场磁共振成像(MRI)和MRI关节造影对犬科动物膝关节进行解剖学研究。
Vet Surg. 2011 Jun;40(4):395-401. doi: 10.1111/j.1532-950X.2011.00823.x. Epub 2011 Mar 21.
9
The elbow.肘部。
Clin Tech Small Anim Pract. 1999 Aug;14(3):177-86. doi: 10.1016/S1096-2867(99)80034-6.
10
[MRI of the regions of the inner ear and cerebellopontine angle using a 3D T2-weighted turbo spin-echo sequence. Comparison with conventional 2D T2-weighted turbo spin-echo sequences and T1-weighted spin-echo sequences].[使用三维T2加权快速自旋回波序列对内耳及桥小脑角区域进行磁共振成像。与传统二维T2加权快速自旋回波序列及T1加权自旋回波序列的比较]
Rofo. 1997 Oct;167(4):377-83. doi: 10.1055/s-2007-1015547.