Suppr超能文献

脉冲磁场疗法床垫对人体的暴露:三种商业产品的数值案例研究。

Human exposure from pulsed magnetic field therapy mats: a numerical case study with three commercial products.

作者信息

De Santis Valerio, Douglas Mark, Nadakuduti Jagadish, Benkler Stefan, Chen Xi Lin, Kuster Niels

机构信息

Foundation for Research on Information Technologies in Society, Zurich, Switzerland.

出版信息

Bioelectromagnetics. 2015 Feb;36(2):149-61. doi: 10.1002/bem.21894. Epub 2015 Jan 16.

Abstract

A previous study found that incident magnetic field exposure from pulsed magnetic field therapy (PMFT) mats can exceed ICNIRP 1998 reference levels. Due to the popularity of PMFT mats for private therapeutic use, regulators need to know if the products are compliant with the basic restrictions and how overexposure can be determined. This case study's objective was to test if such products are intrinsically compliant with ICNIRP 1998 and ICNIRP 2010 basic restrictions by evaluating three different commercially-available PMFT products. In the first step, experimentally validated numerical models of these mats were developed. As a second step, the induced fields were evaluated in high-resolution anatomical models of the IT'IS Virtual Population for various lying positions and compared to the safety guidelines. As expected, a strong influence of exposure on the PMFT design, anatomy, lying position and body orientation was found. The maximum exposure of one PMFT exceeds 3.1 times the basic restrictions of ICNIRP 1998 for the central nervous system tissues and 1.36 times the limit of ICNIRP 2010 for the peripheral tissues. Body loops can significantly increase the electric fields close to the skin, e.g., when the hand and thigh are in contact during mat use. In conclusion, PMFT products are not intrinsically compliant with ICNIRP 1998 and ICNIRP 2010 basic restrictions and therefore require special considerations.

摘要

先前的一项研究发现,脉冲磁场疗法(PMFT)床垫产生的入射磁场暴露可能超过国际非电离辐射防护委员会(ICNIRP)1998年的参考水平。由于PMFT床垫在私人治疗用途中很受欢迎,监管机构需要了解这些产品是否符合基本限制以及如何确定过度暴露情况。本案例研究的目的是通过评估三种不同的市售PMFT产品,来测试此类产品是否本质上符合ICNIRP 1998年和ICNIRP 2010年的基本限制。第一步,开发了这些床垫的经过实验验证的数值模型。第二步,在IT'IS虚拟人群的高分辨率解剖模型中,针对各种躺卧姿势评估感应场,并与安全指南进行比较。不出所料,发现暴露对PMFT的设计、解剖结构、躺卧姿势和身体方位有很大影响。一种PMFT产品的最大暴露量超过了ICNIRP 1998年对中枢神经系统组织的基本限制的3.1倍,以及ICNIRP 2010年对外周组织限制的1.36倍。身体环路会显著增加靠近皮肤处的电场,例如在使用床垫时手和大腿接触的情况下。总之,PMFT产品本质上不符合ICNIRP 1998年和ICNIRP 2010年的基本限制,因此需要特别考虑。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验