Suppr超能文献

Radiographic evaluation of immediately loaded implants supporting 2-3 units fixed bridges in the posterior maxilla: a 3-year follow-up prospective randomized controlled multicenter clinical study.

作者信息

Cesaretti Gianfranco, Botticelli Daniele, Renzi Antonio, Rossi Marcello, Rossi Riccardo, Lang Niklaus P

机构信息

Faculty of Dentistry, University of Medical Science, La Habana, Cuba.

ARDEC, Ariminum Odontologica, Rimini, Italy.

出版信息

Clin Oral Implants Res. 2016 Apr;27(4):399-405. doi: 10.1111/clr.12565. Epub 2015 Feb 9.

Abstract

OBJECTIVE

To compare the survival rate and alveolar bone levels at implants installed in healed sites and functionally loaded within 1 h from installation or after 3 months.

MATERIAL AND METHODS

A total of 30 patients (17 male and 13 female) were recruited and 71 implants with a SLA(®) surface, 4.1 mm in diameter and 8-12 mm long, were installed in a fully healed alveolar ridge, 36 as test and 35 as control implants. The test implants were immediately loaded with a temporary reconstruction in proper occlusion, while the randomly selected control sites received the final reconstruction after 3 months. Radiographic bone levels were determined after implant installation, prosthesis delivery, and at annual intervals thereafter.

RESULTS

One patient of the control and one patient of the test were excluded from evaluation. No further losses of implants or patients were seen up to the 3-year follow-up. Hence, data from 28 patients were accounted for. A total of 37 and 36 metal-ceramic crowns were provided at the test and control sites, respectively. No biological and technical complications were observed during the 3-year follow-up. Bone levels at the time of implant installation were at 1.6 ± 0.8 and 1.7 ± 0.9 mm from the implant shoulder at the test and control sites, respectively. At prosthesis delivery, the bone levels were located at 2.4 ± 0.7 mm at the control sites 3 months after implant placement. After 1 year of function, similar bone levels were observed at both sites, displaying 2.4 ± 1.0 and 2.5 ± 0.8 mm at the test and control sites, respectively. No differences were found in the subsequent observation periods.

CONCLUSION

Survival rates and radiographic bone levels after 1, 2, and 3 years of observation did not differ between conventionally installed implants loaded immediately or delayed (after 3 months). Moreover, insertion torque values did not affect osseointegration.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验