Wilkins Ruth C, Beaton-Green Lindsay A, Lachapelle Sylvie, Kutzner Barbara C, Ferrarotto Catherine, Chauhan Vinita, Marro Leonora, Livingston Gordon K, Boulay Greene Hillary, Flegal Farrah N
Health Canada, Environmental Radiation and Health Sciences Directorate , Ottawa, ON , Canada.
Int J Radiat Biol. 2015 May;91(5):443-51. doi: 10.3109/09553002.2015.1012305. Epub 2015 Feb 27.
To evaluate the importance of annual intercomparisons for maintaining the capacity and capabilities of a well-established biodosimetry network in conjunction with assessing efficient and effective analysis methods for emergency response.
Annual intercomparisons were conducted between laboratories in the Canadian National Biological Dosimetry Response Plan. Intercomparisons were performed over a six-year period and comprised of the shipment of 10-12 irradiated, blinded blood samples for analysis by each of the participating laboratories. Dose estimates were determined by each laboratory using the dicentric chromosome assay (conventional and QuickScan scoring) and where possible the cytokinesis block micronucleus (CBMN) assay. Dose estimates were returned to the lead laboratory for evaluation and comparison.
Individual laboratories performed comparably from year to year with only slight fluctuations in performance. Dose estimates using the dicentric chromosome assay were accurate about 80% of the time and the QuickScan method for scoring the dicentric chromosome assay was proven to reduce the time of analysis without having a significant effect on the dose estimates. Although analysis with the CBMN assay was comparable to QuickScan scoring with respect to speed, the accuracy of the dose estimates was greatly reduced.
Annual intercomparisons are necessary to maintain a network of laboratories for emergency response biodosimetry as they evoke confidence in their capabilities.
评估年度比对对于维持一个成熟的生物剂量测定网络的能力以及评估应急响应有效分析方法的重要性。
在加拿大国家生物剂量测定响应计划中的各实验室之间进行年度比对。比对在六年期间进行,包括向每个参与实验室运送10 - 12份经辐照、盲法处理的血液样本以供分析。各实验室使用双着丝粒染色体分析(传统和快速扫描计分法)以及在可能的情况下使用胞质分裂阻断微核(CBMN)分析来确定剂量估计值。剂量估计值返回牵头实验室进行评估和比较。
各实验室每年的表现相当,仅在性能上有轻微波动。使用双着丝粒染色体分析的剂量估计约80%的时间是准确的,并且用于双着丝粒染色体分析计分的快速扫描方法被证明可减少分析时间,且对剂量估计没有显著影响。尽管CBMN分析在速度方面与快速扫描计分相当,但剂量估计的准确性大大降低。
年度比对对于维持应急响应生物剂量测定实验室网络是必要的,因为它们能唤起对其能力的信心。