Suppr超能文献

Trunnion corrosion as a cause of recurrent pseudotumor.

作者信息

Zylberberg Alejandro D, Catelas Isabelle, Gala Luca, Kim Paul R

机构信息

Division of Orthopedics, Hospital del Trabajador, Ramón Carnicer 185, Providencia Parada de MetroParque Bustamante, Santiago, Chile.

Department of Mechanical Engineering, University of Ottawa, 161 Louis Pasteur, Ottawa, Ontario K1N 6N5 Canada ; Department of Surgery, University of Ottawa, 451 Smyth Road, Ottawa, Ontario K1H 8M5 Canada ; Department of Biochemistry, Microbiology and Immunology, University of Ottawa, 451 Smyth Road, Ottawa, Ontario K1H 8M5 Canada.

出版信息

HSS J. 2015 Feb;11(1):90-3. doi: 10.1007/s11420-014-9430-8. Epub 2015 Jan 30.

Abstract
摘要

相似文献

1
Trunnion corrosion as a cause of recurrent pseudotumor.
HSS J. 2015 Feb;11(1):90-3. doi: 10.1007/s11420-014-9430-8. Epub 2015 Jan 30.
2
3
Trunnion corrosion in metal-on-polyethylene hip arthroplasty: a simple diagnosis and treatment?
Bone Joint J. 2018 Jul;100-B(7):898-902. doi: 10.1302/0301-620X.100B7.BJJ-2017-1127.R2.
4
Will New Metal Heads Restore Mechanical Integrity of Corroded Trunnions?
J Arthroplasty. 2017 Apr;32(4):1356-1359. doi: 10.1016/j.arth.2016.10.007. Epub 2016 Oct 11.
5
Taper-Trunnion Interface Stress Varies Significantly With Head Size and Activity.
J Arthroplasty. 2019 Jan;34(1):157-162. doi: 10.1016/j.arth.2018.09.004. Epub 2018 Sep 22.
6
Metal-on-Metal Compared With Metal-on-Polyethylene: The Effect on Trunnion Corrosion in Total Hip Arthroplasty.
J Arthroplasty. 2017 Aug;32(8):2574-2579. doi: 10.1016/j.arth.2017.03.012. Epub 2017 Mar 29.
9
There Is No Significant Difference in Fretting and Corrosion at the Trunnion of Metal and Ceramic Heads.
Orthopedics. 2019 Jan 1;42(1):e99-e103. doi: 10.3928/01477447-20181206-03. Epub 2018 Dec 13.
10
Trunnion Failure of the Recalled Low Friction Ion Treatment Cobalt Chromium Alloy Femoral Head.
J Arthroplasty. 2017 Sep;32(9):2857-2863. doi: 10.1016/j.arth.2017.03.075. Epub 2017 Apr 8.

本文引用的文献

1
Changes in blood ion levels after removal of metal-on-metal hip replacements: 16 patients followed for 0-12 months.
Acta Orthop. 2014 Jun;85(3):259-65. doi: 10.3109/17453674.2014.913223. Epub 2014 Apr 23.
2
A safe zone for acetabular component position in metal-on-metal hip resurfacing arthroplasty: winner of the 2012 HAP PAUL award.
J Arthroplasty. 2013 Aug;28(7):1224-30. doi: 10.1016/j.arth.2013.02.033. Epub 2013 Mar 26.
3
Pseudotumors are common in well-positioned low-wearing metal-on-metal hips.
Clin Orthop Relat Res. 2012 Jul;470(7):1895-906. doi: 10.1007/s11999-011-2201-7.
6
Histological features of pseudotumor-like tissues from metal-on-metal hips.
Clin Orthop Relat Res. 2010 Sep;468(9):2321-7. doi: 10.1007/s11999-010-1372-y.
7
Necrotic and inflammatory changes in metal-on-metal resurfacing hip arthroplasties.
Acta Orthop. 2009 Dec;80(6):653-9. doi: 10.3109/17453670903473016.
8
Hip resurfacings revised for inflammatory pseudotumour have a poor outcome.
J Bone Joint Surg Br. 2009 Aug;91(8):1019-24. doi: 10.1302/0301-620X.91B8.22562.
9
2008 John Charnley award: metal ion levels after metal-on-metal total hip arthroplasty: a randomized trial.
Clin Orthop Relat Res. 2009 Jan;467(1):101-11. doi: 10.1007/s11999-008-0540-9. Epub 2008 Oct 15.
10
Corrosion of a hip stem with a modular neck taper junction: a retrieval study of 16 cases.
J Arthroplasty. 2009 Oct;24(7):1019-23. doi: 10.1016/j.arth.2008.09.009. Epub 2008 Oct 5.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验