一次性软性隐形眼镜佩戴对角膜厚度、曲率和体积改变的评估。

Assessment of modifications in thickness, curvatures, and volume upon the cornea caused by disposable soft contact lens wear.

作者信息

Del Águila-Carrasco Antonio J, Domínguez-Vicent Alberto, Pérez-Vives Cari, Ferrer-Blasco Teresa, Montés-Micó Robert

机构信息

From the Optometry Research Group, Department of Optics, University of Valencia, Valencia - Spain.

出版信息

Eur J Ophthalmol. 2015 Sep-Oct;25(5):385-90. doi: 10.5301/ejo.5000592. Epub 2015 Mar 16.

Abstract

PURPOSE

To assess the effect of different disposable soft contact lenses on several corneal parameters-thickness, anterior and posterior curvature, and volume-by means of a Scheimpflug imaging-based device (Pentacam HR). Diurnal variations of these parameters were taken into account.

METHODS

Twenty-one young, healthy subjects wore 4 different types of daily disposable soft contact lenses on 4 different days: Dailies AquaComfort Plus, SofLens, Dailies Total1, and Acuvue TruEye. The lenses had different material and water content. Pachymetry and curvature maps and corneal volume values were obtained using the Pentacam HR twice a day: one before putting the lens on and one after an 8-hour period of contact lens wear. Measurements were also taken without any contact lenses being worn.

RESULTS

Regarding corneal thickness, the lens with the most similar behavior to the naked eye scenario was the Dailies Total1, causing a thickening of 0.2 ± 0.1% in the central zone and 0.6 ± 0.2% in the periphery. All 4 lenses caused a slight but not significant flattening in the anterior corneal curvature, whereas the posterior corneal curvature only experienced a significant but small steepening with the SofLens. The use of these lenses increased corneal volume slightly.

CONCLUSIONS

Variations in corneal parameters seem to depend on the type of contact lens used (material, oxygen transmissibility, water content). However, the magnitude of the changes introduced by the use of soft contact lenses over the 8-hour period was small and probably not large enough to influence either visual acuity or comfort.

摘要

目的

通过基于Scheimpflug成像的设备(Pentacam HR)评估不同一次性软性隐形眼镜对几个角膜参数(厚度、前后曲率和体积)的影响。同时考虑这些参数的昼夜变化。

方法

21名年轻健康受试者在4个不同日期佩戴4种不同类型的日抛软性隐形眼镜:Dailies AquaComfort Plus、SofLens、Dailies Total1和Acuvue TruEye。这些镜片具有不同的材料和含水量。每天使用Pentacam HR获取两次测厚、曲率图和角膜体积值:一次在佩戴镜片前,一次在佩戴隐形眼镜8小时后。也在未佩戴任何隐形眼镜的情况下进行测量。

结果

关于角膜厚度,与裸眼情况行为最相似的镜片是Dailies Total1,其导致中央区增厚0.2±0.1%,周边增厚0.6±0.2%。所有4种镜片均导致角膜前表面曲率略有变平,但不显著,而后表面曲率仅在使用SofLens时出现显著但微小的变陡。使用这些镜片会使角膜体积略有增加。

结论

角膜参数的变化似乎取决于所使用的隐形眼镜类型(材料、透氧性、含水量)。然而,在8小时内使用软性隐形眼镜所引起的变化幅度较小,可能不足以影响视力或舒适度。