PURPOSE

The purpose of this study is to compare the visual performance provided by different daily disposable contact lenses and to analyze its variation over time.

METHODS

Visual performance was evaluated in terms of visual acuity (VA) and contrast sensitivity (CS) in 15 myopic subjects (-0.50 to -4.00 diopters) who had been previously fitted with each one of the following seven types of soft contact lenses: DAILIES TOTAL1 (Alcon, Forth Worth, TX), DAILIES AquaComfort Plus (Alcon), 1-DAY ACUVUE TruEye (Johnson & Johnson Vision Care, Jacksonville, FL), 1-DAY ACUVUE MOIST (Johnson & Johnson Vision Care), SofLens daily disposable (Bausch & Lomb, Rochester, NY), Proclear 1 Day (CooperVision, Fairport, NY), and Clariti 1-Day (Sauflon, Twickenham, United Kingdom). We measured VA at three contrast levels (10%, 50%, and 100%) and CS for three spatial frequencies (10, 20, and 25 cycles/degree). These measurements were performed at 2-hr intervals during a 12-hr period of continuous wearing. Measurements were also performed with ophthalmic lenses before contact lens fitting.

RESULTS

Two-way analysis of variance (ANOVA) results revealed significant differences across the lens types and over time for low-contrast VA only. For high- and medium-contrast VA, ophthalmic lens performed better than the contact lenses after 12 hr of use (without statistical differences among the contact lenses). Contrast sensitivity values also showed differences across lenses for the three spatial frequencies under analysis. For each particular lens type, no CS variations were observed with wearing time. Although some of the differences were not statistically significant, we found that, for many of the VA and CS measures, ophthalmic lens and DAILIES TOTAL1 yielded better values than the 1-DAY ACUVUE TruEye and Clariti 1-Day.

CONCLUSIONS

Assessing VA at different contrasts and CS measurements allowed us to perform a visual function evaluation. Contact lens characteristics such as material and water content, among others, may be the cause of the differences in visual performance that emerged from this study. Our findings provide useful information for contact lens practitioners.

摘要

目的

本研究旨在比较不同日抛型隐形眼镜提供的视觉性能,并分析其随时间的变化。

方法

对15名近视受试者(-0.50至-4.00屈光度)的视力(VA)和对比敏感度(CS)进行评估,这些受试者之前已佩戴过以下七种类型的软性隐形眼镜中的每一种:DAILIES TOTAL1(爱尔康公司,得克萨斯州沃思堡)、DAILIES AquaComfort Plus(爱尔康)、1-DAY ACUVUE TruEye(强生视力健公司,佛罗里达州杰克逊维尔)、1-DAY ACUVUE MOIST(强生视力健公司)、SofLens日抛型(博士伦公司,纽约州罗切斯特)、Proclear 1 Day(库博光学公司,纽约州费尔波特)和Clariti 1-Day(索弗隆公司,英国特威克纳姆)。我们在三种对比度水平(10%、50%和100%)下测量视力,并在三种空间频率(10、20和25周/度)下测量对比敏感度。这些测量在连续佩戴12小时期间每隔2小时进行一次。在佩戴隐形眼镜之前,还用眼科镜片进行了测量。

结果

双向方差分析(ANOVA)结果显示,仅在低对比度视力方面,不同镜片类型之间以及随时间存在显著差异。对于高对比度和中等对比度视力,使用12小时后,眼科镜片的表现优于隐形眼镜(隐形眼镜之间无统计学差异)。在所分析的三种空间频率下,对比敏感度值在不同镜片之间也存在差异。对于每种特定的镜片类型,未观察到对比敏感度随佩戴时间的变化。尽管有些差异没有统计学意义,但我们发现,对于许多视力和对比敏感度测量指标,眼科镜片和DAILIES TOTAL1的表现优于1-DAY ACUVUE TruEye和Clariti 1-Day。

结论

在不同对比度下评估视力和进行对比敏感度测量使我们能够进行视觉功能评估。隐形眼镜的材料和含水量等特性可能是本研究中出现的视觉性能差异的原因。我们的研究结果为隐形眼镜从业者提供了有用的信息。