Tomura Noriaki, Mizuno Yasuaki, Saginoya Toshiyuki
Department of Neuroradiology and Radiology, Southern Tohoku Research Institute for Neuroscience, Southern Tohoku General Hospital, Fukushima, Japan
Department of Neuroradiology and Radiology, Southern Tohoku Research Institute for Neuroscience, Southern Tohoku General Hospital, Fukushima, Japan.
Acta Radiol. 2016 Mar;57(3):325-32. doi: 10.1177/0284185115575342. Epub 2015 Mar 19.
Positron emission tomography/computed tomography (PET/CT) using 18 F-fluorodeoxyglucose (FDG) has been used to characterize various malignancies. There are few reports regarding the use of 11 C-methionine (MET)-PET/CT to characterize tumors in the skull base.
To compare MET-PET/CT with FDG-PET/CT in cases of tumors of the skull base.
Both MET-PET/CT and FDG-PET/CT were performed in 27 patients with tumors of the skull base. In all cases, pathology was determined by surgery or biopsy. The images were visually and independently reviewed by two reviewers. For qualitative analysis, the inter-rater agreement between two reviewers was measured. For semi-quantitative evaluation, the tumor-to-normal brain uptake ratios (T/N ratios) were calculated by dividing the maximum of standardized uptake value (SUVmax) for the tumor by the SUVmax of the normal contra-lateral cerebellar hemisphere. Difference in T/N ratios between FDG-PET/CT and MET-PET/CT was analyzed for statistical significance.
On qualitative evaluation, the inter-rater agreement of MET-PET/CT was superior than that of FDG-PET/CT. MET uptake was interpreted as positive in every tumor by both reviewers. MET-PET/CT had a significantly higher T/N ratio than FDG-PET/CT (2.96 ± 1.25 vs. 1.02 ± 0.54, respectively; P < 0.001).
MET-PET/CT showed superior inter-rater agreement and had higher uptake for tumors at the skull base than FDG-PET/CT. The present study suggests that MET-PET/CT has superior potential for imaging of tumors of the skull base.
使用18F-氟脱氧葡萄糖(FDG)的正电子发射断层扫描/计算机断层扫描(PET/CT)已被用于各种恶性肿瘤的特征描述。关于使用11C-蛋氨酸(MET)-PET/CT对头颈部肿瘤进行特征描述的报道较少。
比较MET-PET/CT与FDG-PET/CT在头颈部肿瘤病例中的应用。
对27例头颈部肿瘤患者进行了MET-PET/CT和FDG-PET/CT检查。所有病例均通过手术或活检确定病理。图像由两名阅片者进行独立的视觉评估。对于定性分析,测量两名阅片者之间的评分者间一致性。对于半定量评估,通过将肿瘤的标准化摄取值(SUVmax)最大值除以对侧正常小脑半球的SUVmax来计算肿瘤与正常脑摄取比值(T/N比值)。分析FDG-PET/CT和MET-PET/CT之间T/N比值的差异有无统计学意义。
在定性评估中,MET-PET/CT的评分者间一致性优于FDG-PET/CT。两名阅片者均将MET摄取解释为每个肿瘤呈阳性。MET-PET/CT的T/N比值显著高于FDG-PET/CT(分别为2.96±1.25和1.02±0.54;P<0.001)。
MET-PET/CT显示出更好的评分者间一致性,并且与FDG-PET/CT相比,对头颈部肿瘤的摄取更高。本研究表明,MET-PET/CT在头颈部肿瘤成像方面具有更好的潜力。