Pigolkin Iu I, Skovorodnikov S V, Dubrovin I A
Sud Med Ekspert. 2014 May-Jun;57(3):19-21.
The objective of the present study was to develop the criteria for forensic-medical diagnostics of an electrical injury inflicted in the aqueous environment based on the characteristics of the electrical mark. The specific morphological features of the electrical injuries inflicted in the aqueous environment that were discovered in the materials available for the forensic medical expertise were analysed taking into consideration the results of the relevant research reported in the forensic medical literature. It was shown that an electrical injury inflicted in the aqueous environment results in the formation of an unusual mark in the form of blisters containing no watery liquid associated with electrogenic oedema in the surrounding tissues. Macroscopic and microscopic studies of the electrical mark failed to reveal the signs of grade III and IV grade thermal burning or thermally affected hair. It is concluded that the consistent characteristics of the electrical mark resulting from the injury inflicted by technical electricity in the aqueous environment include cell lengthening, blister formation inside the corneal layer, and the separation of epidermis from the skin proper.