Suppr超能文献

Vaginal mesh for prolapse: a long-term prospective study of 218 mesh kits from a single centre.

作者信息

Karmakar Debjyoti, Hayward Lynsey, Smalldridge Jackie, Lin Sylvia

机构信息

Division of Urogynaecology, Middlemore Hospital, Counties Manukau District health Board, Auckland, New Zealand,

出版信息

Int Urogynecol J. 2015 Aug;26(8):1161-70. doi: 10.1007/s00192-015-2658-0. Epub 2015 Mar 24.

Abstract

INTRODUCTION AND HYPOTHESIS

The aim was to assess the long-term surgical outcomes and complications in patients undergoing mesh-augmented vaginal repair of pelvic organ prolapse.

METHODS

This is a report of a prospective long-term follow-up experience from the Urogynaecological Service, Counties Manukau District Health Board (CMDHB), Auckland, New Zealand. The subjects were 158 symptomatic women undergoing mesh-augmented prolapse repair (218 kits, Feb 2005 to July 2013) using the Apogee and/or Perigee kits (with IntePro mesh until November 2009, and IntePro Lite mesh thereafter). A dedicated electronic database was used.

RESULTS

The median follow-up times were 138 and 105 weeks for the Apogee and Perigee kits, respectively; 56.6% and 48.8% of these kits, respectively, were inserted for recurrent prolapse. Cure rates for prolapse using mesh kits in patients with a history of native tissue POP repair in the same compartment were 90.91% for the anterior compartment (60 of 66) and 95.74% for the posterior compartment (45 of 47). The cumulative mesh extrusion/exposure rate was 15.8% of patients (11.5% of mesh kits) and was significantly higher with the Apogee kit than with the Perigee kit (P = 0.03). The rate of extrusion/exposure was significantly lower with IntePro Lite than with IntePro (P = 0.04 for Perigee and P = 0.0001 for Apogee). There was a significantly higher rate of extrusion/exposure with the Perigee kit in women with previous anterior compartment native tissue repair than with the Apogee kit in women with previous posterior compartment native tissue repair (21.2% versus 6.4%; P = 0.03). Only 8% of extrusions/exposures needed revision of the mesh. A set of significant predictors of mesh extrusion/exposure was identified. Overall success rates were 81.4% (110/135) for the Perigee kit and 74.7% (62/83) for the Apogee kit.

CONCLUSIONS

This is one of the longest prospective mesh follow-up studies to date from a single centre and highlights the need for continuing surveillance despite high overall success rates.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验