Volkova I A, Talan A E, Buchneva E A, Shcherbo S N
Klin Lab Diagn. 2014 Nov;59(11):37-9.
The volume of urine of high power field of analyzer Iris IQ 200 TM was identified according standard of stabilizing erythrocytes and amounted up to 0.18 mkl. The amount of urine corpuscles detected by analyzer in this volume corresponds to amount of urine corpuscles under microscopy of sediment often times concentrated urine at thickness of preparation in 0.1 mm, under microscope with objective x40 and ocular 10/18. The count of corpuscles by analyzer in 1 mkl of urine is the most objective and convenient technique for quantitative evaluation of urine corpuscles.