Law Cristina Llerena, Siu Matt, Modica Patricia, Backus Benjamin
*OD, FAAO †BS ‡PhD Graduate Center for Vision Research, SUNY State College of Optometry, New York, New York (all authors).
Optom Vis Sci. 2015 May;92(5):551-8. doi: 10.1097/OPX.0000000000000576.
Amblyopes do not reliably show relative afferent pupillary defects with full-field stimulation, but amblyopia has cortical involvement; hence, stimuli that engage cortex may be able to reveal pupil defects in amblyopes.
Pupillary responses were acquired with a binocular infrared pupillometer (RAPDx, Konan Medical USA, Irvine, CA) from 15 amblyopic subjects (anisometropic and small-angle strabismic) and 10 age-matched control subjects. Stimuli were a full-field white flash (330 cd/m) or a small (4 degrees) annulus at one of three contrast levels (0.3, 0.6, and 1.8) on a dim background (6.2 cd/m). Stimulus duration was 100 milliseconds, and the interstimulus duration was 2000 milliseconds.
In all four stimulus conditions, the difference in percent contraction amplitude for right versus left eye stimulation was more variable across amblyopes than across control subjects. Amblyopic eyes did not show a specific deficit for the full-field flash. However, the mid-contrast (0.6) annulus stimulus revealed a deficit in the amblyopic eye, whereas the size of the deficit did not correlate with the type or depth of the amblyopia.
Targets of appropriate pattern, brightness, and contrast that select for cortical contributions to the pupil response may be useful for eliciting pupil defects in amblyopic patients. Pupil analysis in this population could prove useful for diagnostic or prognostic value, for example, to determine which amblyopes will respond best to treatment.
弱视患者在全视野刺激下并不能可靠地表现出相对性传入瞳孔障碍,但弱视涉及皮质;因此,能激活皮质的刺激可能会揭示弱视患者的瞳孔缺陷。
使用双目红外瞳孔计(RAPDx,美国科南医疗公司,加利福尼亚州欧文市)记录15名弱视受试者(屈光参差性和小角度斜视性)和10名年龄匹配的对照受试者的瞳孔反应。刺激物为全视野白色闪光(330坎德拉/平方米)或在昏暗背景(6.2坎德拉/平方米)下三种对比度水平(0.3、0.6和1.8)之一的小(4度)环形物。刺激持续时间为100毫秒,刺激间隔时间为2000毫秒。
在所有四种刺激条件下,弱视患者左右眼刺激的收缩幅度百分比差异比对照受试者更具变异性。弱视眼在全视野闪光时未表现出特定缺陷。然而,中等对比度(0.6)的环形物刺激揭示了弱视眼的缺陷,而缺陷大小与弱视类型或严重程度无关。
选择能激活皮质对瞳孔反应的具有适当图案、亮度和对比度的刺激物,可能有助于引出弱视患者的瞳孔缺陷。对该人群进行瞳孔分析可能对诊断或预后评估有帮助,例如确定哪些弱视患者对治疗反应最佳。