Suppr超能文献

[Evaluation methods of angiogenesis in experimental liver fibrosis].

作者信息

Zhao Zhimin, Guo Tao, Yang Shuohui, Pan Kai, Tan Ye, Chen Gaofeng, Liu Chenghai

机构信息

Institute of LiverDiseases, Shuguang Hospital Affiliated to Shanghai University of Traditional Chinese Medicine, Shanghai 201203, China.

出版信息

Zhonghua Gan Zang Bing Za Zhi. 2015 Feb;23(2):107-11. doi: 10.3760/cma.j.issn.1007-3418.2015.02.007.

Abstract

OBJECTIVE

To investigate the methods for assessing angiogenesis in experimental liver fibrosis.

METHODS

Male C57BL/6 mice were randomly divided into a normal (unmodeled) group and a liver fibrosis model group.The model was established by a 4-week course of 10% CCl4 solution (in olive oil) intraperitoneal injection. Liver vasculature was observed by magnetic resonance (MR),computed tomography (CT),synchrotron radiation X-ray,and von Willibrand factor(vWF) immunofluorescence staining. Liver inflammation and fibrosis were observed by staining with hematoxylin-eosin and Sirius red.The t-test and Pearson's correlation analysis were used for statistical analyses.

RESULTS

Compared with the normal group,the model group had more robust inflammation and fibrosis in liver tissue.The liver tissue in the modeled mice showed significant deceases in MR signal intensity on T2WI before and after enhancement (386.67+/-69.04 vs.492.67+/-112.50,t =-2.456, P=0.026).The liver tissue in the modeled mice also showed significantly decreased enhancement CT values (P < 0.01).Synchrotron radiation X-ray imaging showed that the small vessels in the liver tissues of the modeled mice were significantly increased compared to that in the normal mice (P < 0.01).The MR T2W enhanced signal value (439.67+/-104.80, Pearson's r=0.714, P=0.009) and microvascular relative length (676.53+/-122.75, Pearson's r=0.791, P=0.002) were positive correlated with microvessel density (MVD) (14.50+/-5.95),as shown by detection of labeled vWF.The before and after CT enhancement difference (132.60+/-57.02, Pearson's r=-0.612, P=0.034) was negatively correlated with MVD.

CONCLUSION

s MR,CT and synchrotron radiation X-ray imaging can be used for assessing angiogenesis in liver fibrosis,and the findings from each are correlated with the traditional MVD detection method. The two-dimensional imaging of synchrotron radiation X-ray is more intuitive,and has been confirmed as an effective evaluation method for liver angiogenesis.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验