Wire screens are widely used for sampling radioactive aerosols. The front-to-total activity ratio is a critical factor in describing the self-shielding effect of the wire screens. In this study, computational fluid dynamic method was applied to simulate the deposition of aerosols on the surface of the wire screens. Four different types of screens were investigated for particle size varying from 1 nm to 10 µm. Experimental verification was carried out in a radon chamber. The results showed good agreement between experimental data interception and the simulation. Significant differences on the front-to-total activity ratio for the different types of screens were observed when the size of particle was <20 nm.