BACKGROUND

Metal-on-metal (MoM) hip prostheses were shown to have high failure rates including the formation of periprosthetic cystic masses called periprosthetic pseudotumor collections (PPCs).

PURPOSE

To compare MRI prevalence and size of PPCs in patients after bilateral total-hip-replacement (THR) in which at least one hip was replaced by a MoM prosthesis.

MATERIAL AND METHODS

All sequential MRI examinations of patients with bilateral THR in which at least one is MoM (2010-2013) were retrospectively evaluated. MRIs were analyzed separately by two readers for the presence and size of PPCs. These were compared between MoM and non-MoM implants and between patients with unilateral or bilateral-MoM prostheses. Blood metal ion levels were also compared.

RESULTS

Seventy hips of 35 patients (male:female ratio, 9:26; mean age, 64 years; age range, 35-82 years) were assessed. Sixteen patients (45%) underwent bilateral MoM-THRs and 19 (55%) had one MoM and the other non-MoM, yielding 51 MoM THRs and 19 non-MoM THRs. Twenty-eight PPCs were detected in 19 patients (54%): 26 in MoM THRs (51%) and two in non-MoM THRs (10.5%, P = 0.00009). The mean PPC volume in the MoM implants (107 mm(3)) was higher than that of the non-MoM implants (18 mm(3), P = 0.49). Cobalt/chromium blood levels were 78 µg/L/25 µg/L for bilateral MoM THRs and 21 µg/L/10 µg/L for unilateral MoM implants (P = 0.1 and 0.16, respectively).

CONCLUSION

PPCs are more prevalent in MoM THRs compared to non-MoM THRs. Larger PPC volumes and higher blood metal ion levels were detected in patients with bilateral MoM THRs compared to unilateral MoM THRs (P > 0.05).

摘要

背景

金属对金属(MoM)髋关节假体被证明具有较高的失败率,包括形成称为假体周围囊性肿块的假体周围假瘤(PPCs)。

目的

比较双侧全髋关节置换术(THR)后患者中PPCs的MRI患病率和大小,其中至少一侧髋关节由MoM假体置换。

材料与方法

回顾性评估2010 - 2013年所有双侧THR患者(其中至少一侧为MoM)的连续MRI检查。两名阅片者分别分析MRI,以确定PPCs的存在和大小。对MoM和非MoM植入物之间以及单侧或双侧MoM假体患者之间进行比较。还比较了血液金属离子水平。

结果

评估了35例患者的70个髋关节(男:女比例为9:26;平均年龄64岁;年龄范围35 - 82岁)。16例患者(45%)接受了双侧MoM - THR,19例(55%)一侧为MoM,另一侧为非MoM,共51例MoM THR和19例非MoM THR。在19例患者(54%)中检测到28个PPCs:MoM THR中有26个(51%),非MoM THR中有2个(10.5%,P = 0.00009)。MoM植入物中PPC的平均体积(107 mm³)高于非MoM植入物(18 mm³,P = 0.49)。双侧MoM THR的钴/铬血液水平为78 μg/L / 25 μg/L,单侧MoM植入物为21 μg/L / 10 μg/L(P分别为0.1和0.16)。

结论

与非MoM THR相比,PPCs在MoM THR中更常见。与单侧MoM THR相比,双侧MoM THR患者中检测到更大的PPC体积和更高的血液金属离子水平(P > 0.05)。