种植体基台表面粗糙度和粘结剂类型对种植体支持冠固位力的影响。

The influence of implant abutment surface roughness and the type of cement on retention of implant supported crowns.

作者信息

Reddy S Varalakshmi, Reddy M Sushender, Reddy C Rajaneesh, Pithani Padmaja, R Santosh Kumar, Kulkarni Ganesh

机构信息

Professor & HOD, Department of Prosthodontics, MNR Dental College & Hospital , Sangareddy, Telangana, India .

Senior Lecturer, Department of Prosthodontics, SVS Institute of Dental Sciences , Mahabubnagar, Telangana, India .

出版信息

J Clin Diagn Res. 2015 Mar;9(3):ZC05-7. doi: 10.7860/JCDR/2015/12060.5621. Epub 2015 Mar 1.

Abstract

OBJECTIVES

To provide relative data on the retentive characters of the commonly used cements on different implant abutment surfaces.

MATERIALS AND METHODS

A total of 20 implant abutments were divided into 2 groups. Ten implants were unaltered and ten were air borne particle abraded with 50μ aluminium oxide. Three luting agents (Tempbond, IRM and ImProv) were used to secure the crowns to abutments. All the crowns were removed from the abutment with an Instron machine at 0.5mm per minute and tensile bond strengths were recorded. Statistical analysis was performed using Anova, Paired t-test and Post-Hoc tests.

RESULTS

IRM showed the highest mean tensile strength among the three cements when used with treated and untreated implant abutment surfaces. Change in the abutment surface roughness had no effect on the mean tensile bond strength of TempBond and IRM cements, whereas ImProv cement showed reduced tensile strength with sandblasted surface.

CONCLUSION

When increased retention is required IRM cement with either sandblasted or milled surface could be used and when retrievability is required cements of choice could be either TempBond or ImProv.

摘要

目的

提供常用粘结剂在不同种植体基台表面的固位特性相关数据。

材料与方法

总共20个种植体基台被分为2组。10个种植体未作处理,10个用50μm氧化铝进行空气颗粒研磨。使用三种粘结剂(临时粘结剂、IRM和ImProv)将牙冠固定到基台上。所有牙冠均用Instron机器以每分钟0.5mm的速度从基台上移除,并记录拉伸粘结强度。使用方差分析、配对t检验和事后检验进行统计分析。

结果

当与处理过和未处理过的种植体基台表面一起使用时,IRM在三种粘结剂中显示出最高的平均拉伸强度。基台表面粗糙度的变化对临时粘结剂和IRM粘结剂的平均拉伸粘结强度没有影响,而ImProv粘结剂在喷砂表面显示出拉伸强度降低。

结论

当需要增加固位力时,可以使用表面喷砂或研磨的IRM粘结剂;当需要可拆除性时,可选择的粘结剂可以是临时粘结剂或ImProv。

相似文献

1
The influence of implant abutment surface roughness and the type of cement on retention of implant supported crowns.
J Clin Diagn Res. 2015 Mar;9(3):ZC05-7. doi: 10.7860/JCDR/2015/12060.5621. Epub 2015 Mar 1.
3
Cement selection for implant-supported crowns fabricated with different luting space settings.
J Prosthodont. 2013 Feb;22(2):112-9. doi: 10.1111/j.1532-849X.2012.00912.x.
7
Cement selection for cement-retained crown technique with dental implants.
J Prosthodont. 2008 Feb;17(2):92-96. doi: 10.1111/j.1532-849X.2007.00262.x. Epub 2007 Oct 30.

引用本文的文献

1
Effects of cementation technique and cement thickness on the retention and amount of excess cement in implant-supported restorations.
Saudi Dent J. 2024 Sep;36(9):1203-1208. doi: 10.1016/j.sdentj.2024.06.018. Epub 2024 Jun 13.
4
An Trial to Estimate the Retention Ability of Luting Agents Utilized with Dental Implant-Supported Prosthesis.
J Pharm Bioallied Sci. 2022 Jul;14(Suppl 1):S541-S544. doi: 10.4103/jpbs.jpbs_150_22. Epub 2022 Jul 13.

本文引用的文献

2
Clinical performance of screw- versus cement-retained fixed implant-supported reconstructions--a systematic review.
Int J Oral Maxillofac Implants. 2014;29 Suppl:84-98. doi: 10.11607/jomi.2014suppl.g2.1.
4
Tensile strength of cementing agents on the CeraOne system of dental prosthesis on implants.
Implant Dent. 2008 Dec;17(4):451-60. doi: 10.1097/ID.0b013e31818c4947.
5
Crown retention and flexural strength of eight provisional cements.
J Prosthet Dent. 2007 Dec;98(6):455-60. doi: 10.1016/S0022-3913(07)60145-0.
6
Cement selection for cement-retained crown technique with dental implants.
J Prosthodont. 2008 Feb;17(2):92-96. doi: 10.1111/j.1532-849X.2007.00262.x. Epub 2007 Oct 30.
9
Retentive strength of metal copings on prefabricated abutments with five different cements.
Clin Implant Dent Relat Res. 2005;7(4):229-34. doi: 10.1111/j.1708-8208.2005.tb00068.x.
10
Retention of luting agents on implant abutments of different height and taper.
Clin Oral Implants Res. 2005 Oct;16(5):594-8. doi: 10.1111/j.1600-0501.2005.01159.x.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验