Suppr超能文献

超声评估确定颈内静脉置管的最佳头部旋转角度

The Optimal Angle of Head Rotation for Internal Jugular Cannulation as Determined by Ultrasound Evaluation.

作者信息

DeAngelis Vincent, Denny John, Chyu Darrick, Jan Thomas, Lemaire Anthony, Chiricolo Antonio, Solina Al

机构信息

Departments of Anesthesia.

Surgery, Rutgers Robert Wood Johnson Medical School, New Brunswick, NJ.

出版信息

J Cardiothorac Vasc Anesth. 2015 Oct;29(5):1257-60. doi: 10.1053/j.jvca.2015.02.007. Epub 2015 Feb 9.

Abstract

OBJECTIVES

The aim of this study was to determine the degree of head rotation that creates the maximal anatomic separation between the right internal jugular vein and the carotid artery.

DESIGN

Single-center prospective, observational cohort study.

SETTING

University medical center.

PARTICIPANTS

Fifty patients aged>21 years and undergoing cardiac surgery.

INTERVENTIONS

An ultrasound machine equipped with a digital caliper was used to determine the relational anatomy of the internal jugular vein and the carotid artery, with patients in the Trendelenburg position at head angles of -15°, 0°,+15°,+30°,+45°,+60°,+75°, and+90°.

MEASUREMENTS AND MAIN RESULTS

When examining the percentage of the internal jugular vein vertical diameter that is not overlapped by the carotid artery (vertically unencumbered), there was a difference between the head angle groups (p<0.01). Unencumbered vertical distance was different between+75° versus 0°, and+75° versus+15°. At+75°, 60.3%±5.3% of the internal jugular vein was unencumbered vertically, whereas at 0°, it was 37.2%±3.9%, and at+15° it was 40.3%±3.8%. Only 72% of the patients were able to position their head at+75°, and 54% of the subjects were able to position their head at+90°.

CONCLUSION

The authors found the internal jugular vein becomes more vertically separated from the carotid artery at more extreme angles of contralateral head rotation.

摘要

目的

本研究旨在确定能使右侧颈内静脉与颈动脉实现最大解剖分离的头部旋转程度。

设计

单中心前瞻性观察性队列研究。

地点

大学医学中心。

参与者

50例年龄大于21岁且正在接受心脏手术的患者。

干预措施

使用配备数字卡尺的超声仪,在患者处于头低脚高位且头部角度分别为-15°、0°、+15°、+30°、+45°、+60°、+75°和+90°时,确定颈内静脉与颈动脉的相关解剖结构。

测量指标及主要结果

在检查颈内静脉垂直直径未被颈动脉重叠的百分比(垂直无阻碍)时,各头部角度组之间存在差异(p<0.01)。+75°与0°以及+75°与+15°时的无阻碍垂直距离不同。在+75°时,60.3%±5.3%的颈内静脉垂直无阻碍,而在0°时为37.2%±3.9%,在+15°时为40.3%±3.8%。只有72%的患者能够将头部定位在+75°,54%的受试者能够将头部定位在+90°。

结论

作者发现,在对侧头部旋转角度更大时,颈内静脉与颈动脉在垂直方向上的分离更为明显。