Capillary electrophoresis and UV-visible absorbance detection are used with sample stacking to achieve detection limits ranging from 0.2 to 2 ng/mL (0.8 to 6 nM) for steroids. Stacking is accomplished using negatively charged cyclodextrin steroid-carrier molecules at a discrete pH interface between the reconstituted sample and the separation electrolyte. Steroids are then separated in under 5 min using capillary electrophoresis that incorporates secondary equilibria via sodium dodecyl sulfate and cyclodextrin. The effectiveness of the method for measurements of multiple steroids in limited sample volumes is demonstrated in individual female fish with total circulating blood volumes of 5 μL or less. Steroid recoveries from plasma following a sample processing method developed with commercial extraction cartridges range from 81 to 109 % for 17α,20β-dihydroxy-pregn-4-en-3-one, testosterone, 11-ketotestosterone, estrone, 17β-estradiol, and 17α-ethinyl estradiol. When applied to reproductively active female zebrafish, changes were detected in the levels of circulating steroids as a result of exposure to different solvents and 17β-estradiol.
毛细管电泳和紫外可见吸光度检测结合样品堆积技术,可实现对类固醇的检测限为0.2至2 ng/mL(0.8至6 nM)。堆积是通过在重构样品和分离电解质之间的离散pH界面处使用带负电荷的环糊精类固醇载体分子来完成的。然后,使用通过十二烷基硫酸钠和环糊精纳入二次平衡的毛细管电泳,在5分钟内分离类固醇。该方法在总循环血量为5 μL或更少的单个雌鱼中证明了在有限样品体积中测量多种类固醇的有效性。使用商用萃取柱开发的样品处理方法从血浆中回收的17α,20β-二羟基孕-4-烯-3-酮、睾酮、11-酮睾酮、雌酮、17β-雌二醇和17α-乙炔雌二醇的类固醇回收率为81%至109%。当应用于具有生殖活性的雌性斑马鱼时,由于暴露于不同溶剂和17β-雌二醇,检测到循环类固醇水平的变化。