Vitku Jana, Chlupacova Tereza, Sosvorova Lucie, Hampl Richard, Hill Martin, Heracek Jiri, Bicikova Marie, Starka Luboslav
Institute of Endocrinology, Department of Steroids and Proteofactors, Narodni 8, 116 94 Prague, Czech Republic.
Charles University in Prague, Department of Urology, Šrobárova 50, 100 34 Prague, Czech Republic; Faculty Hospital Kralovske Vinohrady, Department of Urology, Šrobárova 50, 100 34 Prague, Czech Republic; Military University Hospital Prague, Department of Urology, U Vojenske nemocnice 1200, 169 02 Prague, Czech Republic.
Talanta. 2015 Aug 1;140:62-67. doi: 10.1016/j.talanta.2015.03.013. Epub 2015 Mar 12.
Bisphenol A (BPA) is a widely known endocrine disruptor with estrogenic, antiestrogenic or antiandrogenic properties. BPA could interfere with estrogen metabolism as well with receptor-mediated estrogen actions. Both environmental BPA and estrogens may be traced in body fluids, of which, besides the blood plasma, the seminal fluid is of particular interest regarding their possible interactions in the testis. The method for simultaneously determining BPA and estrogens is then needed, taking into account that their concentrations in these body fluid may differ. Here the method was developed and validated for measurements of BPA, estrone (E1), estradiol (E2) and estriol (E3) in blood plasma and seminal plasma using liquid chromatography-tandem mass spectrometry. Due to the phenolic moiety of all compounds, dansyl chloride derivatization could be used. The analytical criteria of the method with respect to expected concentration of the analytes were satisfactory. The lower limits of quantifications (LLOQ) amounted to 43.5, 4.0, 12.7, 6.7 pg/mL for plasma BPA, E1, E2 and E3, and 28.9, 4.9, 4.5, 3.4 pg/mL for seminal BPA, E1, E2 and E3, respectively. The concentrations of individual steroids differed between body fluids. To the best of our knowledge, this is the first method that enabled the measurement of estrogens and BPA together in one run. The concentrations of E1, E2 and for the first time also of E3 in seminal plasma in normospermic men are reported.
双酚A(BPA)是一种广为人知的内分泌干扰物,具有雌激素、抗雌激素或抗雄激素特性。双酚A可干扰雌激素代谢以及受体介导的雌激素作用。环境中的双酚A和雌激素均可在体液中检测到,其中,除血浆外,精液因其在睾丸中可能存在的相互作用而备受关注。因此,需要一种同时测定双酚A和雌激素的方法,同时要考虑到它们在这些体液中的浓度可能不同。本文建立并验证了一种使用液相色谱-串联质谱法测定血浆和精浆中双酚A、雌酮(E1)、雌二醇(E2)和雌三醇(E3)的方法。由于所有化合物均含有酚基部分,因此可使用丹磺酰氯衍生化。该方法针对分析物预期浓度的分析标准令人满意。血浆中双酚A、E1、E2和E3的定量下限(LLOQ)分别为43.5、4.0、12.7、6.7 pg/mL,精浆中双酚A、E1、E2和E3的定量下限分别为28.9、4.9、4.5、3.4 pg/mL。不同体液中各甾体激素的浓度有所不同。据我们所知,这是第一种能够一次同时测定雌激素和双酚A的方法。本文还报告了正常精子男性精浆中E1、E2以及首次测定的E3的浓度。