Suppr超能文献

[数字化牙模上咬合平面测定的可重复性和可再现性]

[Reproducibility and repeatability of the determination of occlusal plane on digital dental models].

作者信息

Qin Yi-fei, Xu Tian-min

机构信息

Second Dental Center, Peking University School and Hospital of Stomatology, Beijing 100101, China.

Department of Orthodontics, Peking University School and Hospital of Stomatology, Beijing 100081, China.

出版信息

Beijing Da Xue Xue Bao Yi Xue Ban. 2015 Jun 18;47(3):536-40.

Abstract

OBJECTIVE

To assess the repeatability(intraobserver comparison)and reproducibility(interobserver comparison)of two different methods for establishing the occlusal plane on digital dental models.

METHODS

With Angle's classification as a stratification factor,48 cases were randomly extracted from 806 ones which had integrated clinical data and had their orthodontic treatment from July 2004 to August 2008 in Department of Orthodontics ,Peking University School and Hospital of Stomatology.Post-treatment plaster casts of 48 cases were scanned by Roland LPX-1200 3D laser scanner to generate geometry data as research subjects.In a locally developed software package,one observer repeated 5 times at intervals of at least one week to localize prescriptive landmarks on each digital model to establish a group of functional occlusal planes and a group of anatomic occlusal planes, while 6 observers established two other groups of functional and anatomic occlusal planes independently.Standard deviations of dihedral angles of each group on each model were calculated and compared between the related groups.The models with the five largest standard deviations of each group were studied to explore possible factors that might influence the identification of the landmarks on the digital models.

RESULTS

Significant difference of intraobserver variability was not detected between the functional occlusal plane and the anatomic occlusal plane (P>0.1), while that of interobserver variability was detected (P<0.001). The pooled experimental standard deviation the 6 observers established for the functional occlusal plane was 0.2° smaller than that of the anatomic occlusal plane.The functional occlusal plane's variability of intraobserver and interobsever did not differ significantly (P>0.1), while the anatomic occlusal plane's variability of the intraobserver was significantly smaller than that of the interobserver (P<0.001), with a 0.12° difference value of the pooled experimental standard deviation.

CONCLUSION

When one observer measures a number of digital models,both the functional and the anatomic occlusal planes are suitable as a conference plane with equal repeatability. When several observers measure a large number of digital models,the functional occlusal plane is more reproducible than the anatomic occlusal plane ,but the difference is small.

摘要

目的

评估在数字化牙科模型上建立咬合平面的两种不同方法的可重复性(观察者内比较)和再现性(观察者间比较)。

方法

以安氏分类作为分层因素,从2004年7月至2008年8月在北京大学口腔医学院正畸科接受正畸治疗且有完整临床资料的806例患者中随机抽取48例。用罗兰LPX - 1200 3D激光扫描仪扫描这48例患者治疗后的石膏模型,生成几何数据作为研究对象。在一个自主研发的软件包中,一名观察者每隔至少一周重复5次,在每个数字化模型上定位规定的标志点,以建立一组功能咬合平面和一组解剖咬合平面,同时6名观察者独立建立另外两组功能和解剖咬合平面。计算每个模型上每组二面角的标准差,并在相关组之间进行比较。研究每组中标准差最大的五个模型,以探索可能影响数字化模型上标志点识别的因素。

结果

功能咬合平面和解剖咬合平面之间未检测到观察者内变异性的显著差异(P>0.1),而观察者间变异性存在显著差异(P<0.001)。6名观察者为功能咬合平面建立的合并实验标准差比解剖咬合平面小0.2°。功能咬合平面的观察者内和观察者间变异性无显著差异(P>0.1),而解剖咬合平面的观察者内变异性显著小于观察者间变异性(P<0.001),合并实验标准差差值为0.12°。

结论

当一名观察者测量多个数字化模型时,功能咬合平面和解剖咬合平面作为参考平面都具有同等的可重复性。当多名观察者测量大量数字化模型时,功能咬合平面比解剖咬合平面具有更高的再现性,但差异较小。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验